De Dietrich GT 226A vs GT 227A

Verdict in brief

The GT 226A and GT 227A are adjacent GT 220A sizes — 274 versus 324 MBH gas input, 233 versus 276 MBH output, six versus seven sections. They share R1 1/2 connections and a 7" vent, so the step is a straightforward capacity increment of about 43 MBH for roughly 86 lb more dry weight.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of De Dietrich GT 226A and De Dietrich GT 227A
SpecificationDe Dietrich GT 226ADe Dietrich GT 227A
CSA gas input274 MBH324 MBH
CSA output (gas-oil)233 MBH276 MBH
Published efficiency (as printed)85.2% gas (oil +3 points)85.2% gas (oil +3 points)
Cast-iron sections67
Heating supply / returnR1 1/2 outlet / R1 1/2 returnR1 1/2 outlet / R1 1/2 return
Boiler vent connection7 in7 in
Weight (dry)655 lb741 lb

What actually separates them

Both models sit in the middle of the five-size GT 220A line and share the same physical connection envelope: R1 1/2 heating outlet and return and a 7" vent connection, with the same ASME IV Class 30 60 psi water rating and 230 °F maximum water temperature. The 226A has six cast-iron sections; the 227A has seven.

The printed capacity step is 274 to 324 MBH gas input and 233 to 276 MBH output, with oil input moving from 1.9 to 2.25 GPH. Dry weight rises from 655 to 741 lb. Because the connection sizes do not change between these two, the near-boiler piping plan can stay the same when one replaces the other.

As with the whole GT 220A line, efficiency is published as a single figure — 85.2% on gas, oil +3 points — not per size. The choice between the 226A and 227A should follow the calculated load and the physical space available; the 227A is the larger of the two by one section and about 50 MBH of input.

CurrentSold in Canada
Input
Output (max)
233 MBH
AFUE

The De Dietrich GT 226A is a 6-section eutectic cast-iron 3-pass commercial boiler rated 274 MBH gas input / 233 MBH output (1.9 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with R1 1/2 supply and return connections.

Natural gasPropaneDHW: unknown
CurrentSold in Canada
Input
Output (max)
276 MBH
AFUE

The De Dietrich GT 227A is a 7-section eutectic cast-iron 3-pass commercial boiler rated 324 MBH gas input / 276 MBH output (2.25 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with R1 1/2 supply and return connections.

Natural gasPropaneDHW: unknown

Frequently asked questions

How big is the step between the GT 226A and GT 227A?

The GT 220A brochure prints 274 MBH input / 233 MBH output for the 226A and 324 MBH input / 276 MBH output for the 227A — one more section and about 43 MBH more output.

Do the connections change between these sizes?

No. Both print R1 1/2 supply and return and a 7" vent connection.

Which is the better choice?

That is a heat-loss and plant-layout decision. With identical published efficiency and connections, the deciding factor is whether the load needs the 227A's extra output.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.