Comparison

De Dietrich GT 334A vs GT 339A

Verdict in brief

The GT 334A and GT 339A are the smallest and largest GT 330A sizes: 404 versus 1,442 MBH gas input, 344 versus 1,229 MBH output, and 1,349 versus 2,712 lb dry weight. Both share the printed 85.2% gas efficiency (oil +3 points) and 90 psi ASME IV Class 30 rating; the 334A uses threaded 2-1/2" connections while the 339A uses welded pipe with a distributor tube.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of De Dietrich GT 334A and De Dietrich GT 339A
SpecificationDe Dietrich GT 334ADe Dietrich GT 339A
CSA gas input404 MBH1,442 MBH
CSA output (gas-oil)344 MBH1,229 MBH
Published efficiency (as printed)85.2% gas (oil +3 points)85.2% gas (oil +3 points)
Cast-iron sections49
Heating supply / return2-1/2" threaded female supply and return2-1/2" welded pipe with distributor tube supply and return
Boiler vent connection7 in8 in
Weight (dry)1,349 lb2,712 lb

What actually separates them

The GT 330A line runs six sizes from four to nine sections. The 334A prints 404 MBH gas input and 344 MBH output with a 2.8 GPH oil input; the 339A prints 1,442 MBH input and 1,229 MBH output with 10 GPH oil — a capacity multiple of about 3.5 across the line. Dry weight rises from 1,349 to 2,712 lb.

Connection style changes with size. The 334A and 335A use 2-1/2" threaded female supply and return; from the 336A up, the boiler uses 2-1/2" welded pipe with a distributor tube. The vent connection is 7" on the first three sizes and 8" on the 337A–339A. All sizes are rated ASME IV Class 30 at 90 psi water with an 86–185 °F operating range and a 248 °F maximum water temperature.

Efficiency is one published figure for the line: 85.2% on gas, oil +3 points. The GT 334A through GT 339A submittals are published on DDR Americas letterhead, so each size can be matched to a project drawing. The choice between the two ends is a plant-load and rigging question, not an efficiency one.

CurrentSold in Canada
Input
—
Output (max)
344 MBH
AFUE
—

The De Dietrich GT 334A is a 4-section eutectic cast-iron 3-pass commercial boiler rated 404 MBH gas input / 344 MBH output (2.8 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with 2-1/2" threaded female supply and return.

Natural gasPropaneDHW: unknown
CurrentSold in Canada
Input
—
Output (max)
1,229 MBH
AFUE
—

The De Dietrich GT 339A is a 9-section eutectic cast-iron 3-pass commercial boiler rated 1442 MBH gas input / 1229 MBH output (10 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with 2-1/2" welded pipe with distributor tube supply and return.

Natural gasPropaneDHW: unknown

Frequently asked questions

What is the output range of the GT 330A line?

The brochure prints 344 MBH output for the four-section GT 334A up to 1,229 MBH for the nine-section GT 339A, with gas inputs of 404 to 1,442 MBH.

Do the connections change with size?

Yes. The 334A and 335A use 2-1/2" threaded female connections; the 336A–339A use 2-1/2" welded pipe with a distributor tube.

What water pressure is the GT 330A rated for?

The brochure prints ASME IV Rating Class 30 at 90 psi water for the line.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.