De Dietrich GT 336A vs GT 338A

Verdict in brief

The GT 336A and GT 338A are mid-range GT 330A sizes: 808 versus 1,226 MBH gas input, 688 versus 1,044 MBH output, six versus eight sections. Both use 2-1/2" welded-pipe connections with a distributor tube and share the 85.2% published gas efficiency (oil +3 points); the 338A steps the vent from 7" to 8".

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of De Dietrich GT 336A and De Dietrich GT 338A
SpecificationDe Dietrich GT 336ADe Dietrich GT 338A
CSA gas input808 MBH1,226 MBH
CSA output (gas-oil)688 MBH1,044 MBH
Published efficiency (as printed)85.2% gas (oil +3 points)85.2% gas (oil +3 points)
Cast-iron sections68
Heating supply / return2-1/2" welded pipe with distributor tube supply and return2-1/2" welded pipe with distributor tube supply and return
Boiler vent connection7 in8 in
Weight (dry)1,865 lb2,432 lb

What actually separates them

Both models sit inside the six-size GT 330A line and share the welded-pipe connection arrangement that starts at the 336A: 2-1/2" supply and return with a distributor tube. The 336A is a six-section boiler at 808 MBH input / 688 MBH output with a 5.6 GPH oil rate; the 338A is an eight-section unit at 1,226 MBH input / 1,044 MBH output and 8.5 GPH.

Venting separates them: the brochure prints a 7" vent connection for the 336A and 8" for the 338A. Dry weight rises from 1,865 to 2,432 lb, which matters for rigging and floor loading in a retrofit. The ASME IV Class 30 rating at 90 psi water, 86–185 °F operating range and 248 °F maximum water temperature are shared.

The published efficiency is the same line figure — 85.2% gas, oil +3 points. With connections and efficiency matched, the decision is the plant load: the 338A delivers roughly 356 MBH more output than the 336A, and each size has its own published submittal for project documentation.

CurrentSold in Canada
Input
—
Output (max)
688 MBH
AFUE
—

The De Dietrich GT 336A is a 6-section eutectic cast-iron 3-pass commercial boiler rated 808 MBH gas input / 688 MBH output (5.6 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with 2-1/2" welded pipe with distributor tube supply and return.

Natural gasPropaneDHW: unknown
CurrentSold in Canada
Input
—
Output (max)
1,044 MBH
AFUE
—

The De Dietrich GT 338A is a 8-section eutectic cast-iron 3-pass commercial boiler rated 1226 MBH gas input / 1044 MBH output (8.5 GPH on oil) at a printed 85.2% gas efficiency (oil +3 points), with 2-1/2" welded pipe with distributor tube supply and return.

Natural gasPropaneDHW: unknown

Frequently asked questions

What separates the GT 336A and GT 338A?

Capacity and size: 808 versus 1,226 MBH gas input, six versus eight sections, 1,865 versus 2,432 lb dry, and a 7" versus 8" vent connection.

Are the water connections the same?

Yes. Both use 2-1/2" welded pipe with a distributor tube for supply and return.

Is one more efficient?

No per-size efficiency is printed; the GT 330A brochure gives one published figure of 85.2% on gas with oil +3 points for the line.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate