Dunkirk DCC-150 vs DCC-205

Verdict in brief

The DCC-205 is the top DCC combi: DHW input reaches 205 MBH at 5.0 GPM (70 °F rise) against the DCC-150's 153 MBH and 3.5 GPM, central heating runs to 164 MBH against 125 MBH, and heating capacity rises from 113 to 153 MBH — but the 205 steps up to the deep 21-1/2" cabinet at 125 lb with 1" system connections and 5"/3" coaxial venting.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Dunkirk DCC-150 and Dunkirk DCC-205
SpecificationDunkirk DCC-150Dunkirk DCC-205
Central-heating input, minimum22 MBH29.5 MBH
Central-heating input, maximum125 MBH164 MBH
DHW input, minimum22 MBH29.5 MBH
DHW input, maximum153 MBH205 MBH
DHW flow rate at 70 °F rise3.5 gpm5 gpm
AFUE95 %95 %
Heating capacity113 MBH153 MBH
Net water rating98 MBH133 MBH
Turndown, heating mode5.7:15.5:1
Turndown, DHW mode7:17:1
Dimensions (H x W x D)30" x 17-3/4" x 13-9/16"30" x 17-3/4" x 21-1/2"
Weight103 lb125 lb

What actually separates them

Both are wall-hung combis of the DCC/DCB AI family at 95% AFUE (per the sell sheet). The DCC-150 is the shallow 13-9/16" cabinet at 103 lb; the DCC-205 uses the deep 21-1/2" cabinet at 125 lb with 1-1/4 gallons of water content, 1" system supply/return (G straight thread) and 3/4" copper-sweat DHW connections.

The sell sheet prints CH input of 22-125 MBH on the DCC-150 against 29.5-164 MBH on the DCC-205, heating capacity of 113 versus 153 MBH and net water ratings of 98 versus 133 MBH. DHW input runs 22-153 MBH at 3.5 GPM on the 150 and 29.5-205 MBH at 5.0 GPM on the 205.

The 205's minimum fires (29.5 MBH) sit well above the 150's 22 MBH, so in a low-load building the smaller combi condenses more hours. Both models sit on a page printing '(While supplies last)' with zero current documents, so the comparison is about servicing or finding parts for installed units rather than new purchases.

Dunkirk Boilers

Dunkirk DCC-150

DiscontinuedCanadian status unknown
Input
22–125 MBH
Output (max)
AFUE
95 %

The Dunkirk DCC-150 is the 153 MBH-class combi of the DCC 'AI' condensing line: 22 to 125 MBH central-heating input with DHW input to 153 MBH (3.5 GPM at a 70 °F rise), 95% AFUE and 113 MBH heating capacity. The DCC page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).

Natural gasPropaneCombi

Dunkirk Boilers

Dunkirk DCC-205

DiscontinuedCanadian status unknown
Input
29.5–164 MBH
Output (max)
AFUE
95 %

The Dunkirk DCC-205 is the 205 MBH-class combi of the DCC 'AI' condensing line: 29.5 to 164 MBH central-heating input with DHW input to 205 MBH (5 GPM at a 70 °F rise), 95% AFUE and 153 MBH heating capacity. The DCC page prints '(While supplies last)' with no current documents, so this model is discontinued (sell-through).

Natural gasPropaneCombi

Frequently asked questions

Is the DCC-205's 5.0 GPM a heating figure?

No — it is the combi's DHW flow at a 70 °F temperature rise as printed in the sell sheet table.

Do the two models install the same?

No — the DCC-205 is the deep 21-1/2" cabinet at 125 lb with 1" system connections and 5"/3" coaxial venting, versus 13-9/16" depth, 103 lb, 3/4" connections and 4"/2" coaxial venting on the DCC-150.

Can I still buy a DCC-205?

The official page prints '(While supplies last)' with no current documents — availability is limited to remaining dealer stock; new installations would normally be quoted with Dunkirk's current Royal series instead.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.