Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Dunkirk PSB-4D vs Dunkirk PSB-5D

Verdict in brief

Dunkirk PSB-4D and Dunkirk PSB-5D are two non-condensing boilers from the Dunkirk Boilers PSB Plymouth Steam Boiler line. The Dunkirk PSB-4D is rated 112 MBH input, 91 MBH heating capacity and 82% AFUE, and the Dunkirk PSB-5D is rated 150 MBH input, 122 MBH heating capacity and 82% AFUE. Dunkirk PSB-5D lists 38 MBH more input than Dunkirk PSB-4D (150 MBH against 112 MBH). Both list the same published AFUE of 82%. Dunkirk PSB-5D lists 72 lb more shipping weight than Dunkirk PSB-4D (440 lb against 368 lb).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Dunkirk PSB-4D and Dunkirk PSB-5D
SpecificationDunkirk PSB-4DDunkirk PSB-5D
Efficiency (AFUE)82 %82 %
Shipping weight368 lb440 lb
Dimensions (W x H x D)14-1/2" x 36-3/8 in. x 26-1/2 in.17-3/4" x 36-3/8 in. x 26-1/2 in.
Electrical120 V AC / 60 Hz / 1 phase, less than 12 A (15 A circuit recommended)120 V AC / 60 Hz / 1 phase, less than 12 A (15 A circuit recommended)
FuelNatural gas or propaneNatural gas or propane
Input (natural gas)112 MBH150 MBH
Input (propane)105 MBH140 MBH
Heating capacity (natural gas)91 MBH122 MBH
Heating capacity (propane)85 MBH114 MBH
Net AHRI steam rating (natural gas)68 MBH92 MBH
Net AHRI steam rating (propane)64 MBH86 MBH
Flue diameter6"6"
ConnectionsReturn/supply 2-1/2 in. NPT; gas 1/2 in. NPT (75/112/150) or 3/4 in. NPT (187 MBH and larger)Return/supply 2-1/2 in. NPT; gas 1/2 in. NPT (75/112/150) or 3/4 in. NPT (187 MBH and larger)
ControlElectronic low-water cut-off with 3/4 in. probe, pressure limit control, steam pressure gauge and glass water level gaugeElectronic low-water cut-off with 3/4 in. probe, pressure limit control, steam pressure gauge and glass water level gauge

What actually separates them

Published ratings: the Dunkirk PSB-4D is rated 112 MBH input, 91 MBH heating capacity and 82% AFUE; the Dunkirk PSB-5D is rated 150 MBH input, 122 MBH heating capacity and 82% AFUE. Dunkirk PSB-5D lists 38 MBH more input than Dunkirk PSB-4D (150 MBH against 112 MBH). Both list the same published AFUE of 82%.

Dunkirk PSB-5D lists 72 lb more shipping weight than Dunkirk PSB-4D (440 lb against 368 lb). The dimensions differs: the Dunkirk PSB-4D lists 14-1/2" x 36-3/8 in. x 26-1/2 in., while the Dunkirk PSB-5D lists 17-3/4" x 36-3/8 in. x 26-1/2 in.

Both records print the same AFUE (82%), electrical requirement (120 V AC / 60 Hz / 1 phase, less than 12 A (15 A circuit recommended)), fuel (Natural gas or propane) and flue diameter (6"), per the cited sources.

Dunkirk Boilers

Dunkirk PSB-4D

CurrentCanadian status unknown
Input
Output (max)
AFUE
82 %

The Dunkirk PSB-4D is a current cast-iron gas steam boiler: 112 MBH natural-gas input (105 MBH propane) for 91/85 MBH NG/LP heating capacity, a 68/64 MBH net AHRI steam rating (283/267 sq ft) at 82% AFUE, with a 6" flue and 368 lb shipping.

Natural gasPropaneHeating-only

Dunkirk Boilers

Dunkirk PSB-5D

CurrentCanadian status unknown
Input
Output (max)
AFUE
82 %

The Dunkirk PSB-5D is a current cast-iron gas steam boiler: 150 MBH natural-gas input (140 MBH propane) for 122/114 MBH NG/LP heating capacity, a 92/86 MBH net AHRI steam rating (383/358 sq ft) at 82% AFUE, with a 6" flue and 440 lb shipping.

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The Dunkirk PSB-5D lists 150 MBH, against 112 MBH on the Dunkirk PSB-4D, per the cited documentation.

Which model is more efficient?

Both list the same AFUE of 82%.

How much heavier is the Dunkirk PSB-5D?

It ships at 440 lb against 368 lb for the Dunkirk PSB-4D, per the cited sources.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate