Dunkirk Royal CO-90 vs CH-80

Verdict in brief

The Royal CO-90 and CH-80 are size-equivalents at the bottom of the Royal range — the CO-90 fires 9-80 MBH and the CH-80 8-80 MBH, both at 74 MBH heating capacity and a 64 MBH net AHRI water rating — so the decision is whether the home wants the CO-90's built-in on-demand domestic hot water (90 MBH, 2.5 GPM) or keeps hot water on a separate tank with the heating-only CH-80.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Dunkirk Royal CO-90 and Dunkirk Royal CH-80
SpecificationDunkirk Royal CO-90Dunkirk Royal CH-80
Central-heating input, minimum9 MBH8 MBH
Central-heating input, maximum80 MBH80 MBH
DHW input, minimum9 MBH
DHW input, maximum90 MBH
DHW flow rate at 70 °F rise2.5 gpm
AFUE95.2 %95.2 %
Heating capacity74 MBH74 MBH
Net AHRI water rating64 MBH64 MBH
TurndownUp to 10:1Up to 10:1
Dimensions (H x W x D)28.23" x 17.4" x 16.93"28.23" x 17.4" x 16.93"

What actually separates them

Both models are wall-hung residential Royals at 95.2% AFUE with up to 10:1 turndown in the shared 28.23 x 17.4 x 16.93 in cabinet. The brochure table prints CH input of 9-80 MBH on the CO-90 and 8-80 MBH on the CH-80, with identical heating capacity (74 MBH) and net AHRI water ratings (64 MBH) — the smallest of the 80,000-200,000 BTU/hr combi range and the 80,000-180,000 BTU/hr heating range.

The difference is domestic hot water. The CO-90's DHW side runs 9-90 MBH input at 2.5 GPM and a 70 °F rise and eliminates the separate water heater; the CH-80 produces no DHW, leaving hot water to a tank or water heater (Dunkirk pairs the heat-only models with its optional H2O indirect tanks).

The CO-90's 9 MBH minimum fire is 1 MBH above the CH-80's 8 MBH floor, so day-to-day condensing behaviour is effectively the same; the choice is about hot-water strategy, gas sizing (the combi's DHW draws need the gas line sized for 90 MBH) and what fails independently if one appliance needs service.

Dunkirk Boilers

Dunkirk Royal CO-90

CurrentCanadian status unknown
Input
9–80 MBH
Output (max)
AFUE
95.2 %

The Royal CO-90 is Dunkirk's 90 MBH-class wall-hung residential combi: 9 to 80 MBH central-heating input with DHW input from 9 to 90 MBH (2.5 GPM at a 70 °F rise), 95.2% AFUE, 74 MBH heating capacity and up to 10:1 turndown.

Natural gasPropaneCombi

Dunkirk Boilers

Dunkirk Royal CH-80

CurrentCanadian status unknown
Input
8–80 MBH
Output (max)
AFUE
95.2 %

The Royal CH-80 is Dunkirk's 80 MBH-class wall-hung residential heating-only boiler: 8 to 80 MBH central-heating input at 95.2% AFUE with 74 MBH heating capacity, a 64 MBH net AHRI water rating and up to 10:1 turndown.

Natural gasPropaneHeating-only

Frequently asked questions

Are the CO-90 and CH-80 the same heating output?

Effectively — the brochure table prints 74 MBH heating capacity and a 64 MBH net AHRI water rating for both, with CH input of 9-80 MBH (CO-90) and 8-80 MBH (CH-80).

What does the CO-90 add over the CH-80?

On-demand domestic hot water: DHW input of 9-90 MBH at 2.5 GPM and a 70 °F rise, removing the separate water heater from the system.

When does the CH-80 make more sense?

When the household's hot-water pattern suits a tank or indirect water heater, when the gas line is sized for heating only, or when keeping heating and hot water on separate appliances is preferred.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.