System 2000 EK1 Frontier 80,000 BTU/hr vs 100,000 BTU/hr

Verdict in brief

The System 2000 EK1 Frontier 80,000 BTU/hr and System 2000 EK1 Frontier 100,000 BTU/hr are both non-condensing boilers in the Energy Kinetics System 2000 Frontier line. The System 2000 EK1 Frontier 80,000 BTU/hr is documented at 80,000 BTU/hr input, 69,000 BTU/hr gross output and 86% AFUE, while the System 2000 EK1 Frontier 100,000 BTU/hr is documented at 100,000 BTU/hr input, 85,000 BTU/hr gross output and 85% AFUE. System 2000 EK1 Frontier 100,000 BTU/hr lists 20,000 BTU/hr more input than System 2000 EK1 Frontier 80,000 BTU/hr (100,000 BTU/hr against 80,000 BTU/hr). System 2000 EK1 Frontier 80,000 BTU/hr lists 1 percentage points more AFUE than System 2000 EK1 Frontier 100,000 BTU/hr (86% against 85%). Both list the same published shipping weight of 270 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of System 2000 EK1 Frontier 80,000 BTU/hr and System 2000 EK1 Frontier 100,000 BTU/hr
SpecificationSystem 2000 EK1 Frontier 80,000 BTU/hrSystem 2000 EK1 Frontier 100,000 BTU/hr
Input80,000 BTU/hr100,000 BTU/hr
Gross output (natural gas)69,000 BTU/hr85,000 BTU/hr
Efficiency (AFUE, natural gas)86 %85 %
Domestic hot waterIntegrated system: heat plus domestic hot water from a storage tank using the Energy Manager controlIntegrated system: heat plus domestic hot water from a storage tank using the Energy Manager control
Water content2.5 gal2.5 gal
Energy converter weight270 lb270 lb
VentingChimney venting standard; power-vent chimneyless option availableChimney venting standard; power-vent chimneyless option available
ControlEnergy Manager control (5-year warranty, lifetime protection plan)Energy Manager control (5-year warranty, lifetime protection plan)
FuelNatural gas or propaneNatural gas or propane
Efficiency (AFUE, propane)88 %88 %
Construction3/16" pressure vessel steel throughout; ASME code construction, National Board registered3/16" pressure vessel steel throughout; ASME code construction, National Board registered

What actually separates them

Published ratings: the System 2000 EK1 Frontier 80,000 BTU/hr is rated 80,000 BTU/hr input, 69,000 BTU/hr gross output and 86% AFUE; the System 2000 EK1 Frontier 100,000 BTU/hr is rated 100,000 BTU/hr input, 85,000 BTU/hr gross output and 85% AFUE. System 2000 EK1 Frontier 100,000 BTU/hr lists 20,000 BTU/hr more input than System 2000 EK1 Frontier 80,000 BTU/hr (100,000 BTU/hr against 80,000 BTU/hr). System 2000 EK1 Frontier 80,000 BTU/hr lists 1 percentage points more AFUE than System 2000 EK1 Frontier 100,000 BTU/hr (86% against 85%).

Both records print the same domestic-hot-water arrangement (Integrated system: heat plus domestic hot water from a storage tank using the Energy Manager control), boiler water content (2.5 gal), shipping weight (270 lb) and venting (Chimney venting standard; power-vent chimneyless option available), per the cited sources.

CurrentCanadian status unknown
Input
Output (max)
AFUE
86 %

The System 2000 EK1 Frontier 80,000 BTU/hr input row is the smallest EK1 size and the highest printed AFUE row in the line: 69,000 BTU/hr gross output at 86% AFUE on natural gas (70,000 BTU/hr at 88% on propane) through the EK1 energy converter.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE
85 %

The System 2000 EK1 Frontier 100,000 BTU/hr input row is the second EK1 size: 85,000 BTU/hr gross output at 85% AFUE on natural gas (88,000 BTU/hr at 88% on propane) through the EK1 energy converter.

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The System 2000 EK1 Frontier 100,000 BTU/hr lists 100,000 BTU/hr, against 80,000 BTU/hr on the System 2000 EK1 Frontier 80,000 BTU/hr, per the cited documentation.

Which model is more efficient?

The System 2000 EK1 Frontier 80,000 BTU/hr carries the higher published AFUE at 86%, against 85%.

Not sure which one fits your home?