Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Fulton VANTAGE VTG-3000 vs VANTAGE VTG-4000

Verdict in brief

The VANTAGE VTG-4000 adds 1,000,000 BTU/hr of input and 987,000 BTU/hr of output over the VANTAGE VTG-3000 on the same VANTAGE platform. The VTG-4000 is the most efficient size in the line at 96.9% and moves to 6 in flanged water connections and a 12 in combustion-air intake.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Fulton VANTAGE VTG-3000 and Fulton VANTAGE VTG-4000
SpecificationFulton VANTAGE VTG-3000Fulton VANTAGE VTG-4000
Rated input3,000,000 BTU/h4,000,000 BTU/h
Rated output2,889,000 BTU/h3,876,000 BTU/h
AHRI thermal efficiency96.3 %96.9 %
Boiler horsepower (BTS-2000)86116
Water connections4" ANSI 150# FLG6" ANSI 150# FLG
Dry weight5,300 lb6,600 lb
Water volume215 gal275 gal
Typical flow at rated output, 20°F ΔT289 GPM387 GPM

What actually separates them

The VTG-3000 is rated 3,000,000 BTU/hr input and 2,889,000 BTU/hr output with Up to 5:1 (natural gas) turndown; the VTG-4000 is rated 4,000,000 BTU/hr input and 3,876,000 BTU/hr output with Up to 5:1 (natural gas) turndown. Rated efficiency moves from 96.3% on the VTG-3000 to 96.9% on the VTG-4000 in the official thermal-efficiency column.

The VTG-4000 is the most efficient size in the line at 96.9% and moves to 6 in flanged water connections and a 12 in combustion-air intake. Typical flow at a 20°F rise rises from 289 gpm to 387 gpm, which sizes the primary loop. Dry weight steps from 5,300 lb to 6,600 lb, so rigging and floor loading should be checked against the larger unit.

Both sizes are documented in the same official Fulton data sheet, so the choice is a heat-loss and plant-layout decision: size to the design-day load, then verify connection sizes, venting and weight against the sheet for the exact model.

CurrentCanadian status unknown
Input
—
Output (max)
2,889,000 BTU/h
AFUE
—

The Fulton VANTAGE VTG-3000 is a condensing firetube commercial hydronic boiler rated 3,000,000 BTU/hr input and 2,889,000 BTU/hr output at 96.3% thermal efficiency, with up to 5:1 natural-gas turndown per the official Vantage TDS.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
3,876,000 BTU/h
AFUE
—

The Fulton VANTAGE VTG-4000 is a condensing firetube commercial hydronic boiler rated 4,000,000 BTU/hr input and 3,876,000 BTU/hr output at 96.9% thermal efficiency, with up to 5:1 natural-gas turndown per the official Vantage TDS.

Natural gasPropaneHeating-only

Frequently asked questions

What are the VTG-4000 connections?

6 in ANSI 150# flanged water connections, a 2 in gas connection, a 12 in air intake and a 14 in flue per the Vantage Standard TDS.

What flow does the VTG-4000 need?

The TDS prints a typical 387 gpm at a 20°F rise, with no minimum flow requirement.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate