HTP EFT-80 vs EFT-110

Verdict in brief

The EFT-80 and EFT-110 stay in the same compact fire-tube cabinet and add input in the middle of the range: 16,000-80,000 vs 22,000-110,000 BTU/hr, 79 vs 102 MBH capacity, 128 vs 130 lb and 2.2 vs 2.6 gal of water. Both remain 5:1-turndown models with 1" copper SWT connections and 3" (200 ft) venting.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP EFT-80 and HTP EFT-110
SpecificationHTP EFT-80HTP EFT-110
Input rate, minimum16 MBH22 MBH
Input rate, maximum80 MBH110 MBH
Heating capacity79 MBH102 MBH
Shipping weight128 lb130 lb
Boiler water content2.2 gal2.6 gal
Dimensions (W x H x D)17.5" x 32.5" x 17.4"17.5" x 32.5" x 17.4"
CH supply/return connection1" copper SWT1" copper SWT
Venting3" (200 ft combined)3" (200 ft combined)
Turndown5:15:1

What actually separates them

LP-387 prints 30,000 BTU/hr of extra ceiling on the EFT-110 and 23 MBH more heating capacity (102 vs 79 MBH).

The package barely changes: 130 vs 128 lb, 2.6 vs 2.2 gal water, same 17.5 x 32.5 x 17.4 in cabinet, same 1" copper SWT and 3/4" NPTF gas connections.

Both are 5:1-turndown, 30 PSI MAWP and 3"-to-200-ft venting; the EFT-110's 22,000 BTU/hr minimum fire is the trade-off for its larger ceiling.

DiscontinuedCanadian status unknown
Input
16–80 MBH
Output (max)
—
AFUE
—

The HTP EFT-80 is the 80 MBH class model of the retired Elite FT stainless steel fire-tube boiler line: 16,000 to 80,000 BTU/hr input, 79 MBH heating capacity, 128 lb shipping weight and a 5:1 turndown, recorded from the official LP-387 technical table.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
22–110 MBH
Output (max)
—
AFUE
—

The HTP EFT-110 is the 110 MBH class model of the retired Elite FT stainless steel fire-tube boiler line: 22,000 to 110,000 BTU/hr input, 102 MBH heating capacity, 130 lb shipping weight and a 5:1 turndown, recorded from the official LP-387 technical table.

Natural gasPropaneHeating-only

Frequently asked questions

What separates the EFT-80 and EFT-110?

Input ceiling (80,000 vs 110,000 BTU/hr) and capacity (79 vs 102 MBH); the cabinet and connections are the same.

Which one fires lower?

The EFT-80 at 16,000 BTU/hr minimum against 22,000 BTU/hr on the EFT-110.

Are both 5:1 turndown?

Yes — the 5:1 generation covers EFT-55 through EFT-199.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate