HTP EFTU-110WBN vs EFTU-150WBN

Verdict in brief

Moving from the EFTU-110WBN to the EFTU-150WBN keeps the 19.75 x 38.25 x 17 in cabinet and 95% DOE AFUE but grows the package: the 150 ships at 120 lb (122 lb full) with 2.0 gal of water content against the 110's 110 lb and 1.4 gal, and lifts DOE heating capacity from 101 to 138 MBH with the net AHRI rating up from 88 to 120 MBH.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP EFTU-110WBN and HTP EFTU-150WBN
SpecificationHTP EFTU-110WBNHTP EFTU-150WBN
Central-heating input, minimum (natural gas)11 MBH15 MBH
Central-heating input, maximum (natural gas)110 MBH150 MBH
DOE AFUE95 %95 %
Heating capacity (DOE)101 MBH138 MBH
Net AHRI rating, water88 MBH120 MBH
Shipping weight110 lb120 lb
Approximate full boiler weight107 lb122 lb
Boiler water content1.4 gal2 gal
VentingExhaust 2" (6–100 ft) or 3" (6–150 ft); intake 2" (0–100 ft) or 3" (0–150 ft)Exhaust 2" (6–100 ft) or 3" (6–150 ft); intake 2" (0–100 ft) or 3" (0–150 ft)

What actually separates them

Both models are wall-hung heating-only Elite Fire Tube Ultra boilers at 95% DOE AFUE sharing the 19.75 x 38.25 x 17 in cabinet. The 150's larger firing package (15,000–150,000 BTU/hr against 11,000–110,000 BTU/hr) is reflected in the published weights — 120 lb shipping / 122 lb full versus 110 lb / 107 lb — and in boiler water content of 2.0 gal versus 1.4 gal.

Output follows the input: DOE heating capacity rises from 101 to 138 MBH and the net AHRI water rating from 88 to 120 MBH, figures that a heat-loss calculation compares directly against the home's design-day load.

Venting is unchanged between the two (exhaust 2" 6–100 ft or 3" 6–150 ft; intake 2" 0–100 ft or 3" 0–150 ft), as are the 1-1/4" male NPT CH connections and the 15-year registered warranty. Both minimum fires — 11,000 and 15,000 BTU/hr — are low enough that shoulder-season modulation is similar.

CurrentCanadian status unknown
Input
11–110 MBH
Output (max)
—
AFUE
95 %

The HTP EFTU-110WBN is the 110 MBH class wall-hung heating-only model of the Elite Fire Tube Ultra line: 11.0 to 110 MBH central-heating input at 95% DOE AFUE, 101 MBH DOE heating capacity and a 110 lb shipping weight.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
15–150 MBH
Output (max)
—
AFUE
95 %

The HTP EFTU-150WBN is the 150 MBH class wall-hung heating-only model of the Elite Fire Tube Ultra line: 15.0 to 150 MBH central-heating input at 95% DOE AFUE, 138 MBH DOE heating capacity and a 120 lb shipping weight.

Natural gasPropaneHeating-only

Frequently asked questions

Is the EFTU-150WBN a bigger physical unit?

Yes, internally: same 17 in deep cabinet, but 120 lb shipping weight and 2.0 gal water content against 110 lb and 1.4 gal on the 110.

Do the two models print the same efficiency?

Both print 95% DOE AFUE in the official table; only the 85-size EFTU prints 96%.

Which one fits a home with a 120 MBH design load?

Either could, but only the 150 carries 138 MBH of DOE heating capacity with headroom; the 110 caps at 101 MBH. A licensed heat-loss calculation is the reference.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.