HTP EP-220 vs EP-299

Verdict in brief

The EP-299 raises the Elite Premier ceiling to 299,000 BTU/hr and 277 MBH heating capacity, moves the CH connection to 1-1/4" NPTF and uses the taller 36.5 in cabinet. Both keep the 1" NPTF gas inlet and 95% printed AFUE, and the EP-299 shares its printed 211 lb weight and 3.1 gal water content with the EP-301.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP EP-220 and HTP EP-299
SpecificationHTP EP-220HTP EP-299
Input rate, minimum22 MBH30 MBH
Input rate, maximum220 MBH299 MBH
AFUE (as printed)95 %95 %
Heating capacity204 MBH277 MBH
Shipping weight164 lb211 lb
Boiler water content2.6 gal3.1 gal
Dimensions (W x H x D)14.5" x 24.5" x 26.5"14.5" x 36.5" x 24.75"
CH supply/return connection1" NPTF1-1/4" NPTF
Gas supply connection1" NPTF1" NPTF
Venting4" (200 ft) or 6" (275 ft), combined equivalent feet4" (200 ft) or 6" (275 ft), combined equivalent feet

What actually separates them

Input runs 22,000-220,000 BTU/hr on the EP-220 and 30,000-299,000 on the EP-299; heating capacity steps from 204 to 277 MBH in LP-550 Table 4 at 95% printed AFUE each.

The EP-299's CH supply/return connection grows to 1-1/4" NPTF (from 1") per LP-558 and its cabinet changes to 14.5 x 36.5 x 24.75 in; shipping weight rises from 164 to 211 lb and water content from 2.6 to 3.1 gal.

Both use 4" (200 ft) or 6" (275 ft) venting and a 1" NPTF gas inlet; the EP-299's higher 30,000 BTU/hr minimum fire is the trade-off for the extra 73 MBH of capacity.

DiscontinuedCanadian status unknown
Input
22–220 MBH
Output (max)
AFUE
95 %

The HTP EP-220 is the 220 MBH class model of the retired Elite Premier low-mass condensing boiler line: 22,000 to 220,000 BTU/hr input, 95% printed AFUE, 204 MBH heating capacity and a 164 lb shipping weight, recorded from the official retired Elite Premier table.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
30–299 MBH
Output (max)
AFUE
95 %

The HTP EP-299 is the 299 MBH class model of the retired Elite Premier low-mass condensing boiler line: 30,000 to 299,000 BTU/hr input, 95% printed AFUE, 277 MBH heating capacity and a 211 lb shipping weight, recorded from the official retired Elite Premier table.

Natural gasPropaneHeating-only

Frequently asked questions

What CH connection does the EP-299 use?

LP-558 prints 1-1/4" for the 299 and 301 against 1" for the 80 through 220.

Is the EP-299 heavier?

Yes — LP-550 Table 4 prints 211 lb against 164 lb for the EP-220, with 3.1 vs 2.6 gal water content.

Do both print 95% AFUE?

Yes, both print 95% on the retired page table.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate