HTP EP-299 vs EP-301

Verdict in brief

The EP-299 and EP-301 are near-identical twins in LP-550 Table 4 — both 30,000 BTU/hr minimum, 211 lb, 3.1 gal, 14.5 x 36.5 x 24.75 in, 1-1/4" NPTF CH — with the EP-301 adding just 2 MBH of input ceiling (301,000 vs 299,000; 289 vs 277 MBH capacity) and a higher printed 96.1* efficiency figure.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP EP-299 and HTP EP-301
SpecificationHTP EP-299HTP EP-301
Input rate, minimum30 MBH30 MBH
Input rate, maximum299 MBH301 MBH
AFUE (as printed)95 %96.1 %
Heating capacity277 MBH289 MBH
Shipping weight211 lb211 lb
Boiler water content3.1 gal3.1 gal
Dimensions (W x H x D)14.5" x 36.5" x 24.75"14.5" x 36.5" x 24.75"
CH supply/return connection1-1/4" NPTF1-1/4" NPTF
Gas supply connection1" NPTF1" NPTF
Venting4" (200 ft) or 6" (275 ft), combined equivalent feet4" (200 ft) or 6" (275 ft), combined equivalent feet

What actually separates them

LP-550 Table 4 prints the same minimum input (30,000 BTU/hr), shipping weight (211 lb), water content (3.1 gal) and dimensions for both; the EP-301's maximum input is 301,000 against 299,000 BTU/hr.

The retired page table prints 95% for the EP-299 and 96.1* for the EP-301 (asterisk and N/A energy guide as printed), while heating capacity rises from 277 to 289 MBH.

Connection sizes are identical (1-1/4" NPTF CH, 1" NPTF gas) and both use 4"/6" venting, so the two are effectively the same install with a 2 MBH ceiling difference.

DiscontinuedCanadian status unknown
Input
30–299 MBH
Output (max)
AFUE
95 %

The HTP EP-299 is the 299 MBH class model of the retired Elite Premier low-mass condensing boiler line: 30,000 to 299,000 BTU/hr input, 95% printed AFUE, 277 MBH heating capacity and a 211 lb shipping weight, recorded from the official retired Elite Premier table.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
30–301 MBH
Output (max)
AFUE
96.1 %

The HTP EP-301 is the 301 MBH class model of the retired Elite Premier low-mass condensing boiler line: 30,000 to 301,000 BTU/hr input, 96.1% printed AFUE, 289 MBH heating capacity and a 211 lb shipping weight, recorded from the official retired Elite Premier table.

Natural gasPropaneHeating-only

Frequently asked questions

What is the difference between the EP-299 and EP-301?

2 MBH of maximum input (299,000 vs 301,000 BTU/hr) and a printed efficiency step from 95% to 96.1*; the physical package is identical in LP-550 Table 4.

Why does the EP-301 print 96.1*?

The retired page prints 96.1* with an asterisk and N/A in the Energy Guides column; LP-549 prints line figures of up to 96.4% AFUE / 96.5 thermal efficiency.

Which should a project choose?

Either fits the same piping and vent route; the choice is the printed efficiency preference and the 2 MBH ceiling, since the heat-loss calculation rarely splits them.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate