HTP EP-301 vs EP-399

Verdict in brief

The EP-399 tops the Elite Premier line at 40,000-399,000 BTU/hr with 385 MBH heating capacity, a 1-1/2" CH connection, a 14.5 x 36 x 31.75 in cabinet and 256 lb shipping weight. It prints 96.5* efficiency against the EP-301's 96.1*, but its minimum fire is 10,000 BTU/hr higher.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP EP-301 and HTP EP-399
SpecificationHTP EP-301HTP EP-399
Input rate, minimum30 MBH40 MBH
Input rate, maximum301 MBH399 MBH
AFUE (as printed)96.1 %96.5 %
Heating capacity289 MBH385 MBH
Shipping weight211 lb256 lb
Boiler water content3.1 gal3.7 gal
Dimensions (W x H x D)14.5" x 36.5" x 24.75"14.5" x 36" x 31.75"
CH supply/return connection1-1/4" NPTF1-1/2" NPTF
Gas supply connection1" NPTF1" NPTF
Venting4" (200 ft) or 6" (275 ft), combined equivalent feet4" (200 ft) or 6" (275 ft), combined equivalent feet

What actually separates them

Input runs 30,000-301,000 BTU/hr on the EP-301 and 40,000-399,000 on the EP-399; LP-550 Table 4 prints 289 vs 385 MBH heating capacity and the retired page prints 96.1* vs 96.5* efficiency.

The EP-399 moves to a 1-1/2" NPTF CH connection per LP-558 (LP-550 Table 4 prints 1" NPTF in the 399 cell), deepens the cabinet to 31.75 in and adds 45 lb (256 vs 211 lb) with 3.7 vs 3.1 gal water content.

Both share the 1" NPTF gas inlet, 4"/6" venting and 160 PSI MAWP; the EP-399's 40,000 BTU/hr minimum fire is the trade-off for the top-of-line capacity.

DiscontinuedCanadian status unknown
Input
30–301 MBH
Output (max)
AFUE
96.1 %

The HTP EP-301 is the 301 MBH class model of the retired Elite Premier low-mass condensing boiler line: 30,000 to 301,000 BTU/hr input, 96.1% printed AFUE, 289 MBH heating capacity and a 211 lb shipping weight, recorded from the official retired Elite Premier table.

Natural gasPropaneHeating-only
DiscontinuedCanadian status unknown
Input
40–399 MBH
Output (max)
AFUE
96.5 %

The HTP EP-399 is the 399 MBH class model of the retired Elite Premier low-mass condensing boiler line: 40,000 to 399,000 BTU/hr input, 96.5% printed AFUE, 385 MBH heating capacity and a 256 lb shipping weight, recorded from the official retired Elite Premier table.

Natural gasPropaneHeating-only

Frequently asked questions

What is the EP-399's input range?

40,000-399,000 BTU/hr with 385 MBH heating capacity and 96.5* printed efficiency.

What connection does the EP-399 use?

LP-558 prints 1-1/2" for the 399; LP-550 Table 4 prints 1" NPTF in the 399 cell, so Boilers.ca records the specification-sheet value and flags the manual print.

How much heavier is the EP-399?

LP-550 Table 4 prints 256 lb against 211 lb for the EP-301.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate