HTP UFT-120W vs UFT-140W

Verdict in brief

The UFT-120W and UFT-140W are twins inside the same compact 17.5 x 34 x 15.4 in wall cabinet: both weigh 100 lb, fire down to 12,000–14,000 BTU/hr and share every venting and connection detail. The 140 adds 20 MBH of ceiling (133 versus 114 MBH heating capacity) but its printed DOE AFUE, 95.0%, is the lowest in the UFT line.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP UFT-120W and HTP UFT-140W
SpecificationHTP UFT-120WHTP UFT-140W
Input rate, minimum (natural gas)12 MBH14 MBH
Input rate, maximum (natural gas)120 MBH140 MBH
DOE AFUE95.6 %95 %
Heating capacity114 MBH133 MBH
Turndown10:110:1
Venting2" to 50 ft or 3" to 100 ft, combined equivalent feet2" to 50 ft or 3" to 100 ft, combined equivalent feet
Weight, wall-mount model100 lb100 lb
Dimensions, wall model (W x H x D)17.5" x 34" x 15.4"17.5" x 34" x 15.4"

What actually separates them

The 120 and 140 sizes sit in the same compact UFT wall group — 100 lb each in the 17.5 x 34 x 15.4 in cabinet with identical floor-sibling weights (130 lb for UFT-120F and UFT-140F), identical 2"-to-50 ft / 3"-to-100 ft venting and identical 1-1/4" NPT connections.

Input runs 12,000–120,000 BTU/hr on the 120 and 14,000–140,000 BTU/hr on the 140, lifting heating capacity from 114 to 133 MBH. The printed DOE AFUE falls from 95.6% (the group's best) to 95.0% (the UFT line's lowest) at the 140 size.

Below the 120's ceiling the two behave nearly identically in day-to-day operation, so the 140 is justified only by a design-day heat loss that the 114 MBH heating capacity cannot carry. Everything else — warranty, pressures, venting, gas supply — is common to both records.

Status unknownCanadian status unknown
Input
12–120 MBH
Output (max)
AFUE
95.6 %

The HTP UFT-120W is the 120 MBH class wall-mounted model of HTP's Universal Fire Tube (UFT) medium-mass condensing boiler line: 12 to 120 MBH natural-gas input, 95.6% DOE AFUE and 114 MBH heating capacity in a 100 lb wall cabinet.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
14–140 MBH
Output (max)
AFUE
95 %

The HTP UFT-140W is the 140 MBH class wall-mounted model of HTP's Universal Fire Tube (UFT) medium-mass condensing boiler line: 14 to 140 MBH natural-gas input, 95% DOE AFUE and 133 MBH heating capacity in a 100 lb wall cabinet.

Natural gasPropaneHeating-only

Frequently asked questions

Is the UFT-140W a bigger physical unit than the UFT-120W?

No — both are the compact 100 lb wall cabinet at 17.5 x 34 x 15.4 in. The difference is entirely in the firing range.

Why does the larger UFT-140W print a lower AFUE?

The official model table prints 95.0% DOE AFUE for the 140 against 95.6% for the 120 — a per-model published figure, not a trend Boilers.ca generalizes.

Which one should a project pick?

Size from the heat-loss calculation: below roughly 120 MBH the 120 delivers the group's highest printed efficiency, and the 140's extra ceiling only matters when the load needs it.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate