HTP UFT-140W vs UFT-175W

Verdict in brief

The UFT-175W is the first size that leaves the compact UFT cabinet: it moves to the larger 19.7 x 37 x 16.8 in wall frame at 110 lb (140 lb floor) and its minimum fire steps up from 14,000 to 19,900 BTU/hr. It adds 42 MBH of heating capacity (166 versus 133 MBH) and prints 95.9% DOE AFUE — the LP-555 submittal lists its turndown at 8.79:1.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP UFT-140W and HTP UFT-175W
SpecificationHTP UFT-140WHTP UFT-175W
Input rate, minimum (natural gas)14 MBH19.9 MBH
Input rate, maximum (natural gas)140 MBH175 MBH
DOE AFUE95 %95.9 %
Heating capacity133 MBH166 MBH
Turndown10:110:1
Venting2" to 50 ft or 3" to 100 ft, combined equivalent feet2" to 50 ft or 3" to 100 ft, combined equivalent feet
Weight, wall-mount model100 lb110 lb
Dimensions, wall model (W x H x D)17.5" x 34" x 15.4"19.7" x 37" x 16.8"

What actually separates them

The UFT-140W is the top of the compact group — 100 lb at 17.5 x 34 x 15.4 in, 14,000–140,000 BTU/hr input, 133 MBH heating capacity at 95.0% DOE AFUE. The UFT-175W moves to the wider 19.7 x 37 x 16.8 in wall cabinet at 110 lb, with the floor version stepping to 140 lb and the 22 x 48 x 18 in floor frame.

The 175 fires 19,900–175,000 BTU/hr to 166 MBH of heating capacity at 95.9% DOE AFUE, the second-best printed figure in the UFT line. Its minimum fire (19,900 BTU/hr) is well above the 140's 14,000 BTU/hr, so in a low-load home the larger boiler modulates on a higher floor in shoulder seasons.

HTP's own submittal (LP-555) notes the 175,000 BTU/hr models carry a turndown of 8.79 to 1 rather than the family's 10 to 1 claim. Venting rules and connections are otherwise unchanged — 2" to 50 ft or 3" to 100 ft, 1-1/4" NPT CH — so the choice turns on the heat-loss calculation and how low the home actually needs to fire.

Status unknownCanadian status unknown
Input
14–140 MBH
Output (max)
AFUE
95 %

The HTP UFT-140W is the 140 MBH class wall-mounted model of HTP's Universal Fire Tube (UFT) medium-mass condensing boiler line: 14 to 140 MBH natural-gas input, 95% DOE AFUE and 133 MBH heating capacity in a 100 lb wall cabinet.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
19.9–175 MBH
Output (max)
AFUE
95.9 %

The HTP UFT-175W is the 175 MBH class wall-mounted model of HTP's Universal Fire Tube (UFT) medium-mass condensing boiler line: 19.9 to 175 MBH natural-gas input, 95.9% DOE AFUE and 166 MBH heating capacity in a 110 lb wall cabinet.

Natural gasPropaneHeating-only

Frequently asked questions

Does the UFT-175W use a different cabinet?

Yes — the 175 (with the 199) sits in the larger 19.7 x 37 x 16.8 in wall cabinet at 110 lb, while the 140 stays in the compact 100 lb frame.

What is the UFT-175W's turndown?

HTP's LP-555 submittal states the 175,000 BTU/hr models have a turndown of 8.79 to 1, against the 10 to 1 figure the family claims elsewhere.

Is the UFT-175W better in a small home?

Probably not — its 19,900 BTU/hr minimum fire is higher than the 140's 14,000 BTU/hr, so in mild weather it fires on a higher floor. Size from the heat-loss calculation.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.