HTP UFT-175W vs UFT-199W

Verdict in brief

The UFT-175W and UFT-199W are the two largest UFT wall boilers and share the 19.7 x 37 x 16.8 in cabinet at 110 lb, the same 19,900 BTU/hr minimum fire and identical venting and connections. The 199 adds 24 MBH of input ceiling and 23 MBH of heating capacity (189 versus 166 MBH) and prints the line's only 96.0% DOE AFUE.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of HTP UFT-175W and HTP UFT-199W
SpecificationHTP UFT-175WHTP UFT-199W
Input rate, minimum (natural gas)19.9 MBH19.9 MBH
Input rate, maximum (natural gas)175 MBH199 MBH
DOE AFUE95.9 %96 %
Heating capacity166 MBH189 MBH
Turndown10:110:1
Venting2" to 50 ft or 3" to 100 ft, combined equivalent feet2" to 50 ft or 3" to 100 ft, combined equivalent feet
Weight, wall-mount model110 lb110 lb
Dimensions, wall model (W x H x D)19.7" x 37" x 16.8"19.7" x 37" x 16.8"

What actually separates them

Both sizes occupy the wide UFT wall cabinet (19.7 x 37 x 16.8 in) at 110 lb, with floor siblings (UFT-175F / UFT-199F) at 140 lb in the 22 x 48 x 18 in floor frame. Both fire down to the same 19,900 BTU/hr minimum, so below the 175's ceiling day-to-day behaviour is identical.

The 199 raises the ceiling to 199,000 BTU/hr and heating capacity to 189 MBH against the 175's 175,000 BTU/hr and 166 MBH — the extra 24 MBH is pure design-day headroom. Its printed DOE AFUE of 96.0% is the highest in the UFT line and matches the 'up to 96% AFUE' claim on HTP's UFT page.

HTP's submittal notes the 175 MBH models modulate at 8.79:1; the 199's 19,900–199,000 BTU/hr range is the full 10:1 spread. Venting (2" to 50 ft, 3" to 100 ft), 1-1/4" NPT connections and the out-of-the-box 10-year residential warranty are identical on both.

Status unknownCanadian status unknown
Input
19.9–175 MBH
Output (max)
AFUE
95.9 %

The HTP UFT-175W is the 175 MBH class wall-mounted model of HTP's Universal Fire Tube (UFT) medium-mass condensing boiler line: 19.9 to 175 MBH natural-gas input, 95.9% DOE AFUE and 166 MBH heating capacity in a 110 lb wall cabinet.

Natural gasPropaneHeating-only
Status unknownCanadian status unknown
Input
19.9–199 MBH
Output (max)
AFUE
96 %

The HTP UFT-199W is the 199 MBH class wall-mounted model of HTP's Universal Fire Tube (UFT) medium-mass condensing boiler line: 19.9 to 199 MBH natural-gas input, 96% DOE AFUE and 189 MBH heating capacity in a 110 lb wall cabinet.

Natural gasPropaneHeating-only

Frequently asked questions

Are the UFT-175W and UFT-199W the same size physically?

Yes — both weigh 110 lb in the 19.7 x 37 x 16.8 in wall cabinet. Only the firing range and printed efficiency differ.

Which UFT model prints the highest AFUE?

The UFT-199W at 96.0% DOE AFUE, the highest figure in the UFT table and the basis of the family's 'up to 96%' claim.

When is the 199 worth choosing over the 175?

When the heat-loss calculation plus recovery load approaches the 175's 166 MBH heating capacity. Both fire down to 19,900 BTU/hr, so extra ceiling costs nothing in low-fire behaviour.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.