Laars JX075 vs JX100

Verdict in brief

The JX075 and JX100 are adjacent Mini-Therm JX size steps — 75 and 100 in the 50-200 MBTU/h range of Document 1478C — on the same non-condensing platform with LED-based analog diagnostics and no numeric codes on either.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Laars JX075 and Laars JX100
SpecificationLaars JX075Laars JX100
Maximum input (as printed)75 MBH100 MBH
FuelNatural gas or propaneNatural gas or propane
Domestic hot waterNone built in — a DHW relay kit and DHW panel assembly are listed in the manual's replacement-parts sectionsNone built in — a DHW relay kit and DHW panel assembly are listed in the manual's replacement-parts sections
Error reportingNo digital display or numeric codes — Section 11.C troubleshooting table and Section 11.D flow charts use the control LEDs (TEMP ACTIVE, LOW WATER, HI TEMP, TARGET)No digital display or numeric codes — Section 11.C troubleshooting table and Section 11.D flow charts use the control LEDs (TEMP ACTIVE, LOW WATER, HI TEMP, TARGET)

What actually separates them

Both models are covered by the single Mini-Therm JX manual, Document 1478C: a non-condensing gas-fired hydronic design with natural-gas and propane parts sets, altitude groupings, and the twelve-symptom troubleshooting table (11.C) and LED flow charts (11.D) instead of any numeric error display.

The difference between the models is the size column: the JX075 carries the 75 parts column and the JX100 the 100 column. Neither produces domestic hot water internally — the DHW relay kit and panel assembly listed in the parts sections are the accessories for hot-water-demand applications on both.

For a typical detached home the JX100 is the more common landing point of the two, while the JX075 suits smaller houses, suites and low heat-loss buildings. Sizing follows the heat-loss calculation; the manual's service procedures are identical across the steps.

Laars Heating Systems

Laars JX075

CurrentSold in Canada
Input
Output (max)
AFUE

The Laars JX075 is the second Mini-Therm JX size: a non-condensing gas-fired residential hydronic boiler at the 75 step of the 50-200 MBTU/h range, with LED-based analog diagnostics and no digital display.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars JX100

CurrentSold in Canada
Input
Output (max)
AFUE

The Laars JX100 is the mid-range Mini-Therm JX boiler: a non-condensing gas-fired residential hydronic boiler at the 100 size step of the 50-200 MBTU/h range, with LED-based analog diagnostics and no digital display.

Natural gasPropaneHeating-only

Frequently asked questions

What differs between the JX075 and JX100?

The size step only: 75 versus 100 in the parts tables of Document 1478C. The non-condensing design, fuels, LED diagnostics and service guidance are shared.

Which JX manual covers both models?

Document 1478C covers the whole 50-200 MBTU/h Mini-Therm JX line, so one manual serves the JX075, the JX100 and the rest of the series.

Does either model show a digital fault code?

No. The JX has no digital display; diagnosis uses the numbered troubleshooting table and the TEMP ACTIVE, LOW WATER, HI TEMP and TARGET LEDs in the flow charts.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate