Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Laars JX100 vs JX125

Verdict in brief

The JX100 and JX125 are the middle steps of the Mini-Therm JX range — 100 and 125 in the 50-200 MBTU/h line of Document 1478C — identical non-condensing boilers whose only difference is the size column a heat-loss calculation chooses.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Laars JX100 and Laars JX125
SpecificationLaars JX100Laars JX125
Maximum input (as printed)100 MBH125 MBH
FuelNatural gas or propaneNatural gas or propane
Domestic hot waterNone built in — a DHW relay kit and DHW panel assembly are listed in the manual's replacement-parts sectionsNone built in — a DHW relay kit and DHW panel assembly are listed in the manual's replacement-parts sections
Error reportingNo digital display or numeric codes — Section 11.C troubleshooting table and Section 11.D flow charts use the control LEDs (TEMP ACTIVE, LOW WATER, HI TEMP, TARGET)No digital display or numeric codes — Section 11.C troubleshooting table and Section 11.D flow charts use the control LEDs (TEMP ACTIVE, LOW WATER, HI TEMP, TARGET)

What actually separates them

Within the Mini-Therm JX line the JX100 and JX125 sit next to each other in the middle of the six size columns, and the documented differences end at the parts tables: one manual (Document 1478C) covers the whole range, both models use natural gas or propane from the NG/LP parts sets, and both rely on the analog LED diagnostics rather than codes.

Both are heating-only boilers — the DHW relay kit (H2413100 instructions) and DHW panel assembly in the parts sections are the accessory route for hot-water calls — and both need the anti-condensing piping protection the troubleshooting table describes for a non-condensing boiler.

The practical question is the 125 step's extra ceiling: a home whose calculated load runs near the JX100's capacity on a design day, or with an accessory DHW duty on top, is where the JX125 earns its place. Below that, the two boilers run and service identically.

Laars Heating Systems

Laars JX100

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
—

The Laars JX100 is the mid-range Mini-Therm JX boiler: a non-condensing gas-fired residential hydronic boiler at the 100 size step of the 50-200 MBTU/h range, with LED-based analog diagnostics and no digital display.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars JX125

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
—

The Laars JX125 is the upper-mid Mini-Therm JX boiler: a non-condensing gas-fired residential hydronic boiler at the 125 size step of the 50-200 MBTU/h range, with LED-based analog diagnostics and no digital display.

Natural gasPropaneHeating-only

Frequently asked questions

Is the JX125 just a bigger JX100?

Yes — same non-condensing Mini-Therm JX design, same manual (Document 1478C) and diagnostics; the JX125 is the next size column above the JX100 in the parts tables.

What are the JX sizes in order?

The parts tables list six sizes: 50, 75, 100, 125, 150 and 200 (the JX050 through JX200 steps), so the JX125 sits between the JX100 and the JX150.

Can the JX100 or JX125 handle hot water?

Neither is a combi. A DHW relay kit with installation instructions and a DHW panel assembly are listed in the manual's parts sections so a hot-water call can bring the boiler on.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate