Laars Rheos+ RHHH1200 vs RHHH1600

Verdict in brief

The Rheos+ RHHH1200 and RHHH1600 are adjacent condensing commercial sizes: 1,200,000 versus 1,600,000 BTU/hr input, with 6" vent and air connections on the 1200 and a 6" vent with 8" air on the 1600. Both use 2-1/2" NPT water connections.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Laars Rheos+ RHHH 1200 and Laars Rheos+ RHHH 1600
SpecificationLaars Rheos+ RHHH 1200Laars Rheos+ RHHH 1600
Input1,200,000 BTU/hr1,600,000 BTU/hr
Vent outlet connection6 in6 in
Air inlet connection6 in8 in
Water inlet / outlet2-1/2" NPT2-1/2" NPT
Gas connection (standard pack)1" NPT1-1/2" NPT
Vent / air run50 linear ft with 5 elbows50 linear ft with 5 elbows
AltitudeTo 10,000 ft (universal altitude)To 10,000 ft (universal altitude)

What actually separates them

Document 1185B's model identification prints 1,200,000 BTU/hr input for the RHHH1200 and 1,600,000 BTU/hr for the RHHH1600, both with universal altitude operation to 10,000 ft.

The Figure 1 dimensional table prints a 6" vent outlet and 6" air inlet on the RHHH1200, stepping to a 6" vent and 8" air inlet on the RHHH1600; the standard gas connection rises from 1" to 1-1/2".

Both keep 2-1/2" NPT water connections and 50-linear-foot vent/air runs with 5 elbows, and both are covered by the Rheos+ manual Laars files under Discontinued Documents.

Laars Heating Systems

Laars Rheos+ RHHH 1200

DiscontinuedSold in Canada
Input
—
Output (max)
—
AFUE
—

The Laars Rheos+ RHHH 1200 is a discontinued condensing commercial hydronic boiler at 1,200,000 BTU/hr input, with a 6" vent outlet, 6" air inlet, 2-1/2" NPT water connections and a 1" NPT standard gas connection.

Natural gasPropaneHeating-only

Laars Heating Systems

Laars Rheos+ RHHH 1600

DiscontinuedSold in Canada
Input
—
Output (max)
—
AFUE
—

The Laars Rheos+ RHHH 1600 is a discontinued condensing commercial hydronic boiler at 1,600,000 BTU/hr input, with a 6" vent outlet, 8" air inlet, 2-1/2" NPT water connections and a 1-1/2" NPT standard gas connection.

Natural gasPropaneHeating-only

Frequently asked questions

What is the input difference between the RHHH1200 and RHHH1600?

Document 1185B prints 1,200,000 BTU/hr for the RHHH1200 and 1,600,000 BTU/hr for the RHHH1600.

Do the Rheos+ sizes share the same vent size?

The vent outlet is 6" on both; the air inlet steps from 6" on the RHHH1200 to 8" on the RHHH1600.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate