Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Lochinvar Copper-Fin Fan Assisted CBN0747 vs Copper-Fin II CHN0752

Verdict in brief

The fan-assisted CBN0747 and Copper-Fin II CHN0752 are the closest cross-line pair in the family: 350 to 745 MBH versus 250 to 750 MBH, both on 2" NPT water connections and an 8" vent, but the CBN0747 is 84% with two-stage firing and the CHN0752 is 85% with proportional firing up to 4:1 and the SMART SYSTEM control.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar Copper-Fin Fan Assisted CBN0747 and Lochinvar Copper-Fin II CHN0752
SpecificationLochinvar Copper-Fin Fan Assisted CBN0747Lochinvar Copper-Fin II CHN0752
Heating input, minimum350 MBH250 MBH
Heating input, maximum745 MBH750 MBH
Gross output626 MBH638 MBH
Net AHRI water rating544 MBH555 MBH
Efficiency (thermal)84 %85 %
Water content2.4 gal2.4 gal
Space-heating water connections2"2"
Gas connection1-1/4"1-1/4"
Air inlet size8"
Vent size8"8"
FiringTwo-stage (high/low fire)Proportional, up to 4:1 turndown
Shipping weight550 lb543 lb

What actually separates them

The two models nearly touch at the top: the CBN0747 covers 350 to 745 MBH input with 626 MBH gross output and a 544 MBH AHRI net rating at 84%; the CHN0752 covers 250 to 750 MBH input with 638 MBH gross output and a 555 MBH AHRI net rating at 85%. The Copper-Fin II also fires 100 MBH lower at minimum.

Connections and venting are nearly identical: both use 2" NPT water on 6-1/2" centers, a 1-1/4" gas connection and an 8" vent, and both are fan-assisted Category I designs. The CHN0752's submittal adds Category IV AL29-4C stainless and DirectAire/powered sidewall options.

The decision usually comes down to control and cabinet: the CHN0752 carries the SMART SYSTEM cascade control and proportional firing, and weighs 543 lb against the CBN0747's 550 lb; the CBN0747 keeps the simpler two-stage control with diagnostic lights. Both submittals print 10-year heat-exchanger warranties.

CurrentSold in Canada
Input
250–750 MBH
Output (max)
AFUE

The Copper-Fin II CHN0752 reaches 250 to 750 MBH input with 638 MBH gross output and a 555 MBH AHRI net rating at 85% thermal efficiency, closing the 2" water-connection group.

Natural gasPropaneHeating-only

Frequently asked questions

How close are these two sizes?

Very close: 745 versus 750 MBH maximum input and 626 versus 638 MBH gross output, with the same 8" vent, 2" water connections and 1-1/4" gas connections.

Which model fires lower?

The Copper-Fin II CHN0752, whose I&O minimum input is 250 MBH against the fan-assisted CBN0747's 350 MBH.

Which model has the more advanced control?

The CHN0752 with the SMART SYSTEM control, 8-boiler cascade and proportional firing up to 4:1; the CBN0747 uses a two-stage electronic temperature control.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate