Lochinvar Epic EFC110N vs EFC199N

Verdict in brief

The Epic EFC110N and EFC199N are the smallest and largest floor combis: 110 versus 199 MBH input at 95% AFUE, with 102 versus 185 MBH of DOE heating capacity and 2.6 versus 4.8 gpm of DHW at a 77°F rise. The 199 is taller and 31 lb heavier.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar Epic EFC110N and Lochinvar Epic EFC199N
SpecificationLochinvar Epic EFC110NLochinvar Epic EFC199N
Input, minimum11 MBH19.9 MBH
Input, maximum110 MBH199 MBH
Efficiency (AFUE)95 %95 %
DOE heating capacity102 MBH185 MBH
Net AHRI water rating89 MBH161 MBH
DHW delivery at 77°F rise2.6 GPM4.8 GPM
Gas connection1/2"1/2"
Water connection1" / 3/4" DHW1" / 3/4" DHW
Air inlet size3"3"
Vent size3"3"
Shipping weight184 lb215 lb
Turndown10:110:1

What actually separates them

The EFC-Sub-01 submittal lists the EFC110N at 11-110 MBH input, 102 MBH DOE heating capacity and an 89 MBH net AHRI rating; the EFC199N lists 19.9-199 MBH input, 185 MBH DOE capacity and a 161 MBH net AHRI rating.

Domestic hot water delivery runs 2.6 gpm at a 77°F rise on the EFC110N and 4.8 gpm on the EFC199N; shipping weights are 184 lb and 215 lb respectively.

Both use a 1/2" gas connection, 1" boiler water and 3/4" DHW connections and 3" air and vent connections, so the pair is a direct capacity choice within one platform.

CurrentSold in Canada
Input
11–110 MBH
Output (max)
AFUE
95 %

The Lochinvar Epic EFC110N is a floor-standing combination boiler rated 11-110 MBH input, 102 MBH DOE heating capacity and a 89 MBH net AHRI rating at 95% AFUE and delivers 2.6 gpm of domestic hot water at a 77°F temperature rise.

Natural gasPropaneCombi
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
AFUE
95 %

The Lochinvar Epic EFC199N is a floor-standing combination boiler rated 19.9-199 MBH input, 185 MBH DOE heating capacity and a 161 MBH net AHRI rating at 95% AFUE and delivers 4.8 gpm of domestic hot water at a 77°F temperature rise.

Natural gasPropaneCombi

Frequently asked questions

What is the difference between the EFC110N and EFC199N?

Capacity: the EFC110N is 110 MBH input with 102 MBH DOE heating capacity, and the EFC199N is 199 MBH input with 185 MBH DOE heating capacity; both are 95% AFUE floor combis.

Which floor combi makes more hot water?

The EFC199N, at 4.8 gpm at a 77°F rise versus 2.6 gpm on the EFC110N per the EFC-Sub-01 submittal.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate