Lochinvar
Lochinvar Knight XL KBX0800
- Input
- 80–800 MBH
- Output (max)
- —
- AFUE
- —
The Knight XL KBX0800 fires 80 to 800 MBH with 776 MBH gross output and a 675 MBH AHRI net rating at 97% thermal efficiency, keeping 2" water connections with a 6" vent.
Canada-wide gas boiler information · On-site service in Greater Vancouver, BC
Boilers.ca is a brand of ROMA Heating & Cooling · Licensed gas contractor LGA0202903
Comparison
Verdict in brief
The Knight XL KBX1000 tops the commercial Knight XL line: against the KBX0800 it fires 999 MBH instead of 800, prints 969 MBH gross output against 776, steps the water connection to 2-1/2" and the air intake to 6", and weighs 567 lb against 484 — all still at 97% thermal efficiency.
Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.
| Specification | Lochinvar Knight XL KBX0800 | Lochinvar Knight XL KBX1000 |
|---|---|---|
| Heating input, minimum | 80 MBH | 99.9 MBH |
| Heating input, maximum | 800 MBH | 999 MBH |
| Gross output | 776 MBH | 969 MBH |
| Net AHRI water rating | 675 MBH | 843 MBH |
| Efficiency (thermal) | 97 % | 97 % |
| Water content | 7.3 gal | 8.8 gal |
| Space-heating water connections | 2" | 2-1/2" |
| Gas connection | 1-1/4" | 1-1/4" |
| Air inlet size | 4" | 6" |
| Vent size | 6" | 6" |
| Shipping weight | 484 lb | 567 lb |
The KBX0800 and KBX1000 are the largest floor-mounted Knight XLs, both at 97% thermal efficiency with the SMART TOUCH control and 6" vent per the I&O ratings table.
The 1000 is the line's top size at 999,000 BTU/hr: maximum input rises from 800 to 999 MBH, gross output from 776 to 969 MBH and the AHRI net rating from 675 to 843 MBH. Its minimum fire also rises, from 80 to 99.9 MBH, which matters for a building whose shoulder-season load is small relative to the plant.
The connections step at the 1000: water moves from 2" to 2-1/2" and the air intake from 4" to 6". Water content grows from 7.3 to 8.8 gallons and shipping weight from 484 to 567 lb per the submittal, so the mechanical room's layout and crane capacity differ between the two.
Lochinvar
The Knight XL KBX0800 fires 80 to 800 MBH with 776 MBH gross output and a 675 MBH AHRI net rating at 97% thermal efficiency, keeping 2" water connections with a 6" vent.
Lochinvar
The Knight XL KBX1000 tops the commercial Knight XL line at 99.9 to 999 MBH input with 969 MBH gross output and an 843 MBH AHRI net rating at 97% thermal efficiency, stepping to 2-1/2" water and 6" air connections.
The water connection steps from 2" to 2-1/2" and the air intake from 4" to 6"; the vent stays 6" and the gas connection stays 1-1/4". Shipping weight rises to 567 lb per the submittal.
At 99.9 MBH it is the highest minimum in the line, so the boiler is only a good fit when the building's load genuinely approaches the 999 MBH ceiling.
A consultation includes a heat-loss review so the size is right the first time.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.