Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Lochinvar Knight KHN055 vs WHN055

Verdict in brief

The Lochinvar Knight KHN055 and Lochinvar Knight WHN055 are both condensing boilers in the Lochinvar Knight (previous generation WH/KH) line. The Lochinvar Knight KHN055 is documented at 8.2–55 MBH input, 51 MBH gross output and 95% AFUE, while the Lochinvar Knight WHN055 is documented at 11–55 MBH input, 51 MBH gross output and 95% AFUE. Both list the same published input of 55 MBH. Both list the same published AFUE of 95%.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar Knight KHN055 and Lochinvar Knight WHN055
SpecificationLochinvar Knight KHN055Lochinvar Knight WHN055
Heating input, minimum8.2 MBH11 MBH
Heating input, maximum55 MBH55 MBH
Gross output51 MBH51 MBH
Efficiency (AFUE)95 %95 %
Boiler water content2.3 gal2.5 gal
Water connection1"1"
Gas connection1/2"1/2"
Net AHRI water rating44 MBH44 MBH
Vent size2"2"

What actually separates them

Published ratings: the Lochinvar Knight KHN055 is rated 8.2–55 MBH input, 51 MBH gross output and 95% AFUE; the Lochinvar Knight WHN055 is rated 11–55 MBH input, 51 MBH gross output and 95% AFUE. Both list the same published input of 55 MBH. Both list the same published AFUE of 95%.

The boiler water content differs: the Lochinvar Knight KHN055 lists 2.3 gal, while the Lochinvar Knight WHN055 lists 2.5 gal.

Both records print the same input (55 MBH), gross output (51 MBH), AFUE (95%) and water connections (1"), per the cited sources.

DiscontinuedHistorically in Canada
Input
8.2–55 MBH
Output (max)
—
AFUE
95 %

The Lochinvar Knight KHN055 is a discontinued floor-standing fire-tube boiler rated 8.2-55 MBH input with 51 MBH gross output and a 44 MBH net AHRI water rating at 95% AFUE.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
11–55 MBH
Output (max)
—
AFUE
95 %

The Lochinvar Knight WHN055 is a discontinued wall-hung fire-tube boiler rated 11-55 MBH input with 51 MBH gross output and a 44 MBH net AHRI water rating at 95% AFUE.

Natural gasPropaneHeating-only

Frequently asked questions

Do the two models share the same input?

Yes — both list 55 MBH in the cited documentation.

Which model is more efficient?

Both list the same AFUE of 95%.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate