Comparison

Lochinvar Knight KHN199 vs KHN285

Verdict in brief

The legacy Knight KHN199 and KHN285 are the two largest floor-standing fire-tube generations: 20-199 versus 28.5-285 MBH input, 184 versus 264 MBH gross output, both 95% AFUE with 1-1/4" water connections. The 285 adds 80 MBH of gross output and 0.3 gallons more water content.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar Knight KHN199 and Lochinvar Knight KHN285
SpecificationLochinvar Knight KHN199Lochinvar Knight KHN285
Heating input, minimum20 MBH28.5 MBH
Heating input, maximum199 MBH285 MBH
Gross output184 MBH264 MBH
Net AHRI water rating160 MBH229 MBH
Efficiency (AFUE)95 %95 %
Boiler water content5.2 gal4.9 gal
Water connection1-1/4"1-1/4"
Gas connection1/2"1/2"
Vent size3"3"

What actually separates them

The KH 55-285 I&O ratings table lists the KHN199 at 20-199 MBH input, 184 MBH gross output and a 160 MBH net AHRI rating; the KHN285 lists 28.5-285 MBH input, 264 MBH gross output and a 229 MBH net AHRI rating, both at 95% AFUE.

Both print 3" vent sizes, 1-1/4" water connections and a 1/2" gas connection; water content is 5.2 gallons on the KHN199 and 4.9 gallons on the KHN285 per the table.

The KHN generation is discontinued and documented by the archived Rev J I&O manual; the current floor Knight is the KHB line.

DiscontinuedHistorically in Canada
Input
20–199 MBH
Output (max)
AFUE
95 %

The Lochinvar Knight KHN199 is a discontinued floor-standing fire-tube boiler rated 20-199 MBH input with 184 MBH gross output and a 160 MBH net AHRI water rating at 95% AFUE.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
28.5–285 MBH
Output (max)
AFUE
95 %

The Lochinvar Knight KHN285 is a discontinued floor-standing fire-tube boiler rated 28.5-285 MBH input with 264 MBH gross output and a 229 MBH net AHRI water rating at 95% AFUE.

Natural gasPropaneHeating-only

Frequently asked questions

What is the difference between the KHN199 and KHN285?

Capacity: the KHN199 fires 20-199 MBH with 184 MBH gross output and the KHN285 fires 28.5-285 MBH with 264 MBH gross output, both at 95% AFUE.

Where is the KHN manual?

Lochinvar still hosts the KH 55-285 Installation & Operation Manual (Rev J) from the KHN support pages.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate