Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Lochinvar SYNC SBN1300 vs SBN1500

Verdict in brief

Lochinvar SYNC SBN1300 and Lochinvar SYNC SBN1500 are two condensing boilers from the Lochinvar SYNC (SBN, discontinued) line. The Lochinvar SYNC SBN1300 is documented at 130–1,300 MBH input and 1,237 MBH gross output, while the Lochinvar SYNC SBN1500 is documented at 150–1,500 MBH input and 1,444 MBH gross output. Lochinvar SYNC SBN1500 lists 200 MBH more input than Lochinvar SYNC SBN1300 (1,500 MBH against 1,300 MBH).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Lochinvar SYNC SBN1300 and Lochinvar SYNC SBN1500
SpecificationLochinvar SYNC SBN1300Lochinvar SYNC SBN1500
Heating input, minimum130 MBH150 MBH
Heating input, maximum1,300 MBH1,500 MBH
Gross output1,237 MBH1,444 MBH
Water content10 gal11.4 gal
Outlet / inlet water connections3" / (2)-2"3" / (2)-2"
Gas connection1-1/2"1-1/2"
Net AHRI water rating1,076 MBH1,256 MBH
Air size6"6"
Vent size6"6"
AltitudeSea level to 4,500 ft standard; high-altitude build 3,000-12,000 ftSea level to 4,500 ft standard; high-altitude build 3,000-12,000 ft

What actually separates them

Published ratings: the Lochinvar SYNC SBN1300 is rated 130–1,300 MBH input and 1,237 MBH gross output; the Lochinvar SYNC SBN1500 is rated 150–1,500 MBH input and 1,444 MBH gross output. Lochinvar SYNC SBN1500 lists 200 MBH more input than Lochinvar SYNC SBN1300 (1,500 MBH against 1,300 MBH).

The boiler water content differs: the Lochinvar SYNC SBN1300 lists 10 gal, while the Lochinvar SYNC SBN1500 lists 11.4 gal.

Both records print the same water connections (3" / (2)-2"), gas connection (1-1/2"), air size (6") and vent size (6"), per the cited sources.

DiscontinuedHistorically in Canada
Input
130–1300 MBH
Output (max)
—
AFUE
—

The Lochinvar SYNC SBN1300 is a discontinued commercial condensing boiler rated 130-1,300 MBH input with 1,237 MBH gross output and an 1,076 MBH net AHRI water rating, documented on Lochinvar's "Series Discontinued" support page.

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
150–1500 MBH
Output (max)
—
AFUE
—

The Lochinvar SYNC SBN1500 is a discontinued commercial condensing boiler rated 150-1,500 MBH input with 1,444 MBH gross output and an 1,256 MBH net AHRI water rating, documented on Lochinvar's "Series Discontinued" support page.

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The Lochinvar SYNC SBN1500 lists 1,500 MBH, against 1,300 MBH on the Lochinvar SYNC SBN1300, per the cited documentation.

Which model has the higher gross output?

The Lochinvar SYNC SBN1500 lists 1,444 MBH, against 1,237 MBH on the Lochinvar SYNC SBN1300.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate