Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Navien NCB-210 vs NCB-240

Verdict in brief

The NCB-240 tops the original NCB line: 120 MBH heating input against the NCB-210's 100, a 109 MBH capacity against 92 and DHW input of 199,900 BTU/h against 180,000, with flow rising to 4.5 GPM at a 77°F rise. Both weigh 84 lb in the same cabinet and share an 18 MBH minimum fire; the 240 prints 93.3% AFUE against the 210's 93.6%.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Navien NCB-210 and Navien NCB-240
SpecificationNavien NCB-210Navien NCB-240
Heating input, minimum18 MBH18 MBH
Heating input, maximum100 MBH120 MBH
Heating capacity92 MBH109 MBH
Net AHRI water rating80 MBH95 MBH
Efficiency (AFUE)93.6 %93.3 %
DHW input, maximum180 MBH199.9 MBH
DHW flow rate at 77°F (43°C) rise4 GPM4.5 GPM
Weight84 lb84 lb

What actually separates them

The NCB-210 and NCB-240 are the upper pair of Navien's original NCB combi series. The manual prints an 18 MBH minimum fire for both, so low-load behaviour is identical; the difference is the ceiling — 100 against 120 MBH of heating input, 92 against 109 MBH of capacity and an 80 against 95 MBH net AHRI water rating.

On the domestic hot water side the NCB-240 fires to 199,900 BTU/h against the NCB-210's 180,000, with 4.5 GPM against 4.0 GPM at a 77°F (43°C) rise. That is the largest DHW step in the line, and it is what a household with heavy simultaneous draws is paying for; both units keep the same 0.5 GPM minimum and 3/4" DHW connections.

Both models weigh 84 lb in the shared 17 x 28 x 12 in cabinet with 1" NPT heating connections and the same venting options. AFUE is effectively tied (93.3% versus 93.6%), so the choice is a sizing decision: if the heat-loss calculation exceeds 100 MBH or the DHW demand exceeds the 210's range, the 240 is the documented fit; otherwise the 210's slightly higher AFUE is the only measurable difference.

DiscontinuedHistorically in Canada
Input
18–100 MBH
Output (max)
—
AFUE
93.6 %

The Navien NCB-210 is a first-generation wall-hung condensing combi from the discontinued NCB series: 18 to 100 MBH of heating input with 92 MBH heating capacity, 93.6% AFUE and DHW input to 180,000 BTU/h.

Natural gasPropaneCombi
DiscontinuedHistorically in Canada
Input
18–120 MBH
Output (max)
—
AFUE
93.3 %

The Navien NCB-240 is a first-generation wall-hung condensing combi from the discontinued NCB series: 18 to 120 MBH of heating input with 109 MBH heating capacity, 93.3% AFUE and DHW input to 199,900 BTU/h.

Natural gasPropaneCombi

Frequently asked questions

How much more hot water does the NCB-240 make?

Its DHW input ceiling is 199,900 BTU/h against the NCB-210's 180,000, with published flow of 4.5 GPM against 4.0 GPM at a 77°F temperature rise.

Is the NCB-240 heavier than the NCB-210?

No. Both are 84 lb in the same 17 x 28 x 12 in wall-hung cabinet, with identical connections and venting options.

Which should replace a failed NCB-210?

Start from the room-by-room heat-loss calculation and the household's hot-water demand. If either lands above the NCB-210's published ceilings, the 240-class size is the honest basis — and for a new boiler, the current NCB-H line supersedes both.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate