Navien NFB-301C vs NFB-399C

Verdict in brief

The NFB-301C and NFB-399C are the two wall-hung NFB-C commercial boilers and share the 25.1 x 32.8 x 22.3 in cabinet, 97.5% thermal efficiency, 15:1 turndown and 1 1/4" NPT water connections. The 399C fires to 399 MBH instead of 301, delivers 389 MBH against 293 MBH of capacity and a 338 against 255 MBH net AHRI rating, but starts higher (26 MBH minimum), weighs more (278 against 243 lb) and holds more water (9.6 against 7.6 gallons).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Navien NFB-301C and Navien NFB-399C
SpecificationNavien NFB-301CNavien NFB-399C
Input, minimum20 MBH26 MBH
Input, maximum301 MBH399 MBH
Heating capacity293 MBH389 MBH
Net AHRI water rating255 MBH338 MBH
Thermal efficiency97.5 %97.5 %
Turndown ratio15:115:1
Weight243 lb278 lb
Water content7.6 gal9.6 gal
Heating water connections1 1/4" NPT1 1/4" NPT
Gas connection3/4" NPT3/4" NPT
Venting3" or 4" PVC, CPVC, polypropylene or stainless steel, or 3" or 4" special gas vent Type BH (Class III A/B/C)3" or 4" PVC, CPVC, polypropylene or stainless steel, or 3" or 4" special gas vent Type BH (Class III A/B/C)
Max. vent length, 3"60 ft60 ft
Max. vent length, 4"150 ft150 ft

What actually separates them

Both NFB-C models are wall-hung commercial fire-tube condensing boilers rated at a printed 97.5% thermal efficiency with 15:1 turndown, in the same 25.1 x 32.8 x 22.3 in cabinet with 1 1/4" NPT water and 3/4" NPT gas connections. Venting is shared too: 3" or 4" PVC, CPVC, polypropylene or stainless steel (or special gas vent Type BH, Class III A/B/C), to 60 ft in 3" or 150 ft in 4" per the series page.

The 399C adds roughly a third more input at the top: 399 MBH against 301 MBH, with capacity rising from 293 to 389 MBH and the net AHRI water rating from 255 to 338 MBH. Because the series' 20 and 26 MBH minimum inputs are close, the bigger model costs only a little in low-fire behaviour while nearly halving the turndown advantage of the 301C at its low end.

Physically the 399C is the larger appliance inside the same cabinet: 278 lb against 243 lb and 9.6 gallons of water content against 7.6. The choice follows the heat-loss or plant calculation — a load that fits under the 301C's ceiling gets steadier low-fire tracking from the lighter, lower-minimum 301C, while a load approaching 301 MBH points to the 399C at no footprint cost.

CurrentSold in Canada
Input
20–301 MBH
Output (max)
—
AFUE
—

The Navien NFB-301C is the entry model of the wall-hung NFB-C commercial boiler series: 20 to 301 MBH of input with a 293 MBH heating capacity and a 255 MBH net AHRI water rating at 97.5% thermal efficiency, weighing 243 lb empty (307 lb with water).

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
26–399 MBH
Output (max)
—
AFUE
—

The Navien NFB-399C is the top model of the wall-hung NFB-C commercial boiler series: 26 to 399 MBH of input with a 389 MBH heating capacity and a 338 MBH net AHRI water rating at 97.5% thermal efficiency, in the same cabinet as the NFB-301C at 278 lb.

Natural gasPropaneHeating-only

Frequently asked questions

Are the NFB-301C and NFB-399C the same physical size?

Yes. Both measure 25.1 x 32.8 x 22.3 in and share the same connections and venting; the 399C weighs 278 lb against the 301C's 243 lb and holds 9.6 gallons against 7.6.

What are the capacity differences between the two?

The 301C's product page prints a 293 MBH heating capacity with a 255 MBH net AHRI water rating; the 399C prints 389 MBH and 338 MBH respectively, both at 97.5% thermal efficiency.

Which NFB-C model should a project choose?

The 301C suits loads whose calculation fits its 301 MBH ceiling, with a lower 20 MBH minimum and lighter weight. A load approaching that ceiling points to the 399C, whose minimum rises only to 26 MBH.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.