Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

New Yorker CG-F CG40F vs CG50F

Verdict in brief

The New Yorker CG-F CG40F and New Yorker CG-F CG50F are both non-condensing boilers in the New Yorker Boiler CG-F line. The New Yorker CG-F CG40F is documented at 105 MBH input, 88 MBH heating capacity and 84% AFUE, while the New Yorker CG-F CG50F is documented at 140 MBH input, 117 MBH heating capacity and 84% AFUE. New Yorker CG-F CG50F lists 35 MBH more input than New Yorker CG-F CG40F (140 MBH against 105 MBH). Both list the same published AFUE of 84%. New Yorker CG-F CG50F lists 53 lb more shipping weight than New Yorker CG-F CG40F (357 lb against 304 lb).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of New Yorker CG-F CG40F and New Yorker CG-F CG50F
SpecificationNew Yorker CG-F CG40FNew Yorker CG-F CG50F
Input105 MBH140 MBH
DOE heating capacity88 MBH117 MBH
Net AHRI water rating77 MBH102 MBH
Efficiency (AFUE)84 %84 %
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Approx. shipping weight304 lb357 lb
Dimensions (width × height × depth)16" × 40" × 32"19" × 40" × 32"
VentingChimney vented with integral draft diverterChimney vented with integral draft diverter
Supply/return connections1-1/4" supply and 1-1/4" return1-1/4" supply and 1-1/4" return
Gas valve connection1/2"1/2"
ControlIntegrated boiler control with thermal purge and integral LWCOIntegrated boiler control with thermal purge and integral LWCO
FuelNatural gas ('N' suffix) or LP gas ('L' suffix)Natural gas ('N' suffix) or LP gas ('L' suffix)
Vent diameter5"6"

What actually separates them

Published ratings: the New Yorker CG-F CG40F is rated 105 MBH input, 88 MBH heating capacity and 84% AFUE; the New Yorker CG-F CG50F is rated 140 MBH input, 117 MBH heating capacity and 84% AFUE. New Yorker CG-F CG50F lists 35 MBH more input than New Yorker CG-F CG40F (140 MBH against 105 MBH). Both list the same published AFUE of 84%.

New Yorker CG-F CG50F lists 53 lb more shipping weight than New Yorker CG-F CG40F (357 lb against 304 lb). The dimensions differs: the New Yorker CG-F CG40F lists 16" × 40" × 32", while the New Yorker CG-F CG50F lists 19" × 40" × 32". The vent diameter differs: the New Yorker CG-F CG40F lists 5", while the New Yorker CG-F CG50F lists 6".

Both records print the same AFUE (84%), domestic-hot-water arrangement (Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater), venting (Chimney vented with integral draft diverter) and water connections (1-1/4" supply and 1-1/4" return), per the cited sources.

New Yorker Boiler

New Yorker CG-F CG40F

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The New Yorker CG-F CG40F is the third size, stepping to a 5-inch vent: 105 MBH input with 88 MBH DOE heating capacity and a 77 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 5".

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CG-F CG50F

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The New Yorker CG-F CG50F is the mid-size CG-F with a 6-inch vent: 140 MBH input with 117 MBH DOE heating capacity and a 102 MBH net AHRI water rating at 84.0% AFUE, chimney vented in 6".

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The New Yorker CG-F CG50F lists 140 MBH, against 105 MBH on the New Yorker CG-F CG40F, per the cited documentation.

Which model is more efficient?

Both list the same AFUE of 84%.

How much heavier is the New Yorker CG-F CG50F?

It ships at 357 lb against 304 lb for the New Yorker CG-F CG40F, per the cited sources.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate