Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

New Yorker CGS-C CGS30C vs CGS40C

Verdict in brief

Both the New Yorker CGS-C CGS30C and the New Yorker CGS-C CGS40C belong to the New Yorker Boiler CGS-C line of non-condensing boilers. Published ratings: New Yorker CGS-C CGS30C at 69 MBH input, 57 MBH heating capacity and 82% AFUE; New Yorker CGS-C CGS40C at 103 MBH input, 84 MBH heating capacity and 82% AFUE. New Yorker CGS-C CGS40C lists 34 MBH more input than New Yorker CGS-C CGS30C (103 MBH against 69 MBH). Both list the same published AFUE of 82%. New Yorker CGS-C CGS40C lists 70 lb more shipping weight than New Yorker CGS-C CGS30C (420 lb against 350 lb).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of New Yorker CGS-C CGS30C and New Yorker CGS-C CGS40C
SpecificationNew Yorker CGS-C CGS30CNew Yorker CGS-C CGS40C
Input69 MBH103 MBH
DOE heating capacity57 MBH84 MBH
Efficiency (AFUE)82 %82 %
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Approx. ship weight350 lb420 lb
VentingChimney vented with built-in draft diverterChimney vented with built-in draft diverter
Supply/return connections2" supply and 2" return2" supply and 2" return
ControlFully packaged with pressure limit, probe-type LWCO and vent damperFully packaged with pressure limit, probe-type LWCO and vent damper
FuelNatural gas or LP gas (conversion kit)Natural gas or LP gas (conversion kit)
AHRI net steam rating43 MBH63 MBH
Steam square feet179 sq ft263 sq ft
Flue collar diameter4"5"

What actually separates them

Published ratings: the New Yorker CGS-C CGS30C is rated 69 MBH input, 57 MBH heating capacity and 82% AFUE; the New Yorker CGS-C CGS40C is rated 103 MBH input, 84 MBH heating capacity and 82% AFUE. New Yorker CGS-C CGS40C lists 34 MBH more input than New Yorker CGS-C CGS30C (103 MBH against 69 MBH). Both list the same published AFUE of 82%.

New Yorker CGS-C CGS40C lists 70 lb more shipping weight than New Yorker CGS-C CGS30C (420 lb against 350 lb). The flue collar diameter differs: the New Yorker CGS-C CGS30C lists 4", while the New Yorker CGS-C CGS40C lists 5".

Both records print the same AFUE (82%), domestic-hot-water arrangement (Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater), venting (Chimney vented with built-in draft diverter) and water connections (2" supply and 2" return), per the cited sources.

New Yorker Boiler

New Yorker CGS-C CGS30C

CurrentCanadian status unknown
Input
Output (max)
AFUE
82 %

The New Yorker CGS-C CGS30C is the smallest CGS-C steam size: 69 MBH input with 57 MBH DOE heating capacity and a 43 MBH AHRI net steam rating (179 sq ft) at 82% AFUE, chimney vented with a 4" flue collar.

Natural gasPropaneHeating-only

New Yorker Boiler

New Yorker CGS-C CGS40C

CurrentCanadian status unknown
Input
Output (max)
AFUE
82 %

The New Yorker CGS-C CGS40C is the second steam size with a 5-inch flue collar: 103 MBH input with 84 MBH DOE heating capacity and a 63 MBH AHRI net steam rating (263 sq ft) at 82% AFUE, chimney vented with a 5" flue collar.

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The New Yorker CGS-C CGS40C lists 103 MBH, against 69 MBH on the New Yorker CGS-C CGS30C, per the cited documentation.

Which model is more efficient?

Both list the same AFUE of 82%.

How much heavier is the New Yorker CGS-C CGS40C?

It ships at 420 lb against 350 lb for the New Yorker CGS-C CGS30C, per the cited sources.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate