NTI Trinity FTG1200 vs FTG1400

Verdict in brief

The FTG1200 and FTG1400 are the two smallest FTG sizes on NTI's product page and share the same physical class: 1,210 lb, 1 1/4" NPT female gas, 3" grooved water connections and 8 in venting. The 1400 fires 140 to 1400 MBH instead of 120 to 1200 MBH, lifting heating capacity from 1,153 to 1,344 MBH and the Net AHRI rating from 1,003 to 1,169 MBH at 96% thermal efficiency against the 1200's 96.1%.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Trinity FTG1200 and NTI Trinity FTG1400
SpecificationNTI Trinity FTG1200NTI Trinity FTG1400
Input, minimum120 MBH140 MBH
Input, maximum1,200 MBH1,400 MBH
Thermal efficiency96.1 %96 %
Heating capacity1,153 MBH1,344 MBH
Net AHRI rating1,003 MBH1,169 MBH
Weight1,210 lb1,210 lb
Weight, with water1,500 lb1,500 lb
Water connections (inlet / outlet)3" grooved joint3" grooved joint
Gas connection1 1/4" NPT female1 1/4" NPT female
Air inlet size8 in8 in
Flue size8 in8 in
Canada altitude derate10% derate at 2,000–4,500 ft10% derate at 2,000–4,500 ft
Domestic hot waterHeating-only; pair with an indirect tank or separate water heaterHeating-only; pair with an indirect tank or separate water heater

What actually separates them

Both boilers are indoor floor-standing commercial fire-tube units in the same class: 1,210 lb on the product page (1,500 lb with water per the I&O manual), a 1 1/4 in NPT female gas connection, 3 in grooved water connections on inlet and outlet, and 8 in air inlet and flue runs to 150 ft.

NTI lists the FTG1200 at 120 to 1200 MBH input with 96.1% thermal efficiency — the top rating on the FTG table — a 1,153 MBH heating capacity and a 1,003 MBH Net AHRI rating. The FTG1400 fires 140 to 1400 MBH at 96% with a 1,344 MBH heating capacity and a 1,169 MBH Net AHRI rating, so the step adds about 190 MBH of output for one tenth of an efficiency point and a minimum fire that rises from 120 to 140 MBH.

Both are heating-only plant boilers sized from a demand calculation, and the FTG I&O manual requires a 10% Canada altitude derate between 2,000 and 4,500 ft for the family. The 1400 earns its place when plant demand exceeds the 1200's ceiling; loads that fit under 1,200 MBH keep the slightly higher-rated 1200 with its lower minimum fire.

CurrentSold in Canada
Input
120–1200 MBH
Output (max)
AFUE

The NTI Trinity FTG1200 is the entry size of the FTG commercial fire-tube line as NTI's page lists it: 120 to 1200 MBH input at 96.1% thermal efficiency, with a 1,153 MBH heating capacity and a 1,003 MBH Net AHRI rating.

Natural gasHeating-only
CurrentSold in Canada
Input
140–1400 MBH
Output (max)
AFUE

The NTI Trinity FTG1400 lifts the FTG page's entry class to a 1,400 MBH ceiling: 140 to 1400 MBH input at 96% thermal efficiency, with a 1,344 MBH heating capacity and a 1,169 MBH Net AHRI rating.

Natural gasHeating-only

Frequently asked questions

What does the FTG1400 add over the FTG1200?

Input rises from 120–1200 to 140–1400 MBH, heating capacity from 1,153 to 1,344 MBH and the Net AHRI rating from 1,003 to 1,169 MBH; thermal efficiency eases from 96.1% to 96%. Weight, connections and venting are unchanged.

Which FTG model is more efficient?

The FTG1200 at 96.1% thermal efficiency; the FTG1400 is rated 96% per NTI's product table.

Do the two models weigh the same?

Yes — 1,210 lb on the NTI product page for both, with the FTG I&O manual listing the class at 1,500 lb with water.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate