Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

NTI Trinity TFT110 vs TFT154

Verdict in brief

Both the NTI Trinity TFT110 and the NTI Trinity TFT154 belong to the NTI Boilers Trinity TFT (discontinued) line of condensing boilers. Published ratings: NTI Trinity TFT110 at 21.6–108 MBH input, 99 MBH heating capacity and 95% AFUE; NTI Trinity TFT154 at 15.4–154 MBH input, 141 MBH heating capacity and 95% AFUE. NTI Trinity TFT154 lists 46 MBH more input than NTI Trinity TFT110 (154 MBH against 108 MBH). Both list the same published AFUE of 95%.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of NTI Trinity TFT110 and NTI Trinity TFT154
SpecificationNTI Trinity TFT110NTI Trinity TFT154
Input, minimum21.6 MBH15.4 MBH
Input, maximum108 MBH154 MBH
DOE heating capacity99 MBH141 MBH
Efficiency (AFUE)95 %95 %
Domestic hot waterHeating-only; pair with an indirect tank or separate water heaterHeating-only; pair with an indirect tank or separate water heater
Boiler water content3.2 gal3.9 gal
Water connections1" NPT male1" NPT male
Gas connection1/2" NPT male1/2" NPT male
FuelNatural gas or propaneNatural gas or propane
Net I=B=R rating86 MBH122 MBH
Vent / air-inlet diameter2 or 3 in3 in
Vent / air-inlet length2" or 3" runs up to 100 ft each side; on LP the 2" run is limited to 25 ft on the TFT1103" runs up to 150 ft each side
Weight, with water110 lb160 lb
Canada altitude derate10% derate at 2,000–4,500 ft10% derate at 2,000–4,500 ft

What actually separates them

Published ratings: the NTI Trinity TFT110 is rated 21.6–108 MBH input, 99 MBH heating capacity and 95% AFUE; the NTI Trinity TFT154 is rated 15.4–154 MBH input, 141 MBH heating capacity and 95% AFUE. NTI Trinity TFT154 lists 46 MBH more input than NTI Trinity TFT110 (154 MBH against 108 MBH). Both list the same published AFUE of 95%.

The boiler water content differs: the NTI Trinity TFT110 lists 3.2 gal, while the NTI Trinity TFT154 lists 3.9 gal. The vent / air-inlet diameter differs: the NTI Trinity TFT110 lists 2 or 3 in, while the NTI Trinity TFT154 lists 3 in. The vent / air-inlet length differs: the NTI Trinity TFT110 lists 2" or 3" runs up to 100 ft each side; on LP the 2" run is limited to 25 ft on the TFT110, while the NTI Trinity TFT154 lists 3" runs up to 150 ft each side.

Both records print the same AFUE (95%), domestic-hot-water arrangement (Heating-only; pair with an indirect tank or separate water heater), water connections (1" NPT male) and gas connection (1/2" NPT male), per the cited sources.

DiscontinuedHistorically in Canada
Input
21.6–108 MBH
Output (max)
AFUE
95 %

The NTI Trinity TFT110 is a discontinued wall-hung fire-tube condensing boiler: 21.6–108 MBH input with a 99 MBH heating capacity, a 86 MBH Net I=B=R rating and 95% AFUE per the TFT I&O manual (99984535).

Natural gasPropaneHeating-only
DiscontinuedHistorically in Canada
Input
15.4–154 MBH
Output (max)
AFUE
95 %

The NTI Trinity TFT154 is a discontinued wall-hung fire-tube condensing boiler: 15.4–154 MBH input with a 141 MBH heating capacity, a 122 MBH Net I=B=R rating and 95% AFUE per the TFT I&O manual (99984535).

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The NTI Trinity TFT154 lists 154 MBH, against 108 MBH on the NTI Trinity TFT110, per the cited documentation.

Which model is more efficient?

Both list the same AFUE of 95%.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate