P-K MODU-FIRE FD N750 vs N1000

Verdict in brief

The MODU-FIRE FD N750 and N1000 share the same 54" × 32" × 52" shipping box, 800 lb operating weight, 6.2-gallon water content, 116 sq. ft. heated surface, 1-1/4" gas and 2-1/2" water connections and 5:1 turndown; the N1000 adds 250 MBH of input and 212 MBH of output, raises minimum input from 150 to 166 MBH and moves 85 GPM at a 20°F ΔT versus 63.8 GPM.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of P-K MODU-FIRE FD N750 and P-K MODU-FIRE FD N1000
SpecificationP-K MODU-FIRE FD N750P-K MODU-FIRE FD N1000
Minimum input150 MBH166 MBH
Input750 MBH1,000 MBH
Output638 MBH850 MBH
Efficiency (page)88 %88 %
Turndown ratio5:15:1
Main gas connection1 1/4" NPT-F1 1/4" NPT-F
Boiler supply / return2 1/2" NPT (supply F / return M)2 1/2" NPT (supply F / return M)
Operating weight800 lb800 lb
Shipping weight820 lb820 lb
Boiler water content6.2 gal6.2 gal
Boiler HP1925.4
Heated wet surface area116 sq. ft.116 sq. ft.
Flow rate @ 20°F ΔT63.8 GPM85 GPM
Combustion air inlet8" dia. stub8" dia. stub
Exhaust vent6" (5" with adapter)6" (5" with adapter)
Shipping width32 in32 in
Shipping length54 in54 in
Shipping height52 in52 in

What actually separates them

P-K's submittal prints the N750MFD at 750,000 BTU/hr input / 638,000 BTU/hr output with a 150,000 BTU/hr minimum, and the N1000MFD at 1,000,000 / 850,000 with a 166,000 BTU/hr minimum. Both modulate at 5:1.

Everything physical is shared: the same 54" × 32" × 52" shipping dimensions, 800 lb operating and 820 lb shipping weights, 6.2 gallons of water, 116 sq. ft. of heated wet surface, 8" combustion-air stub, 6" exhaust (5" with adapter), 1-1/4" NPT gas and 2-1/2" NPT supply/return connections.

The flow rate at a 20°F ΔT is the practical difference — 63.8 GPM on the N750 against 85 GPM on the N1000 — which sets the near-boiler piping and pump sizing. Both are forced-draft non-condensing boilers requiring Category II or IV venting at up to 88% efficiency.

Patterson-Kelley

P-K MODU-FIRE FD N750

CurrentCanadian status unknown
Input
150–750 MBH
Output (max)
638 MBH
AFUE

The P-K MODU-FIRE FD N750 is a forced-draft non-condensing commercial boiler rated 750 MBH input and 638 MBH output in Patterson-Kelley's published submittal, with 5:1 turndown, a 150 MBH minimum input and a 800 lb operating weight.

Natural gasHeating-only

Patterson-Kelley

P-K MODU-FIRE FD N1000

CurrentCanadian status unknown
Input
166–1000 MBH
Output (max)
850 MBH
AFUE

The P-K MODU-FIRE FD N1000 is a forced-draft non-condensing commercial boiler rated 1000 MBH input and 850 MBH output in Patterson-Kelley's published submittal, with 5:1 turndown, a 166 MBH minimum input and a 800 lb operating weight.

Natural gasHeating-only

Frequently asked questions

Do they share the same weight and dimensions?

Yes — both print 800 lb operating / 820 lb shipping and a 54" × 32" × 52" shipping box on the submittal.

What is the flow difference?

63.8 GPM for the N750MFD and 85 GPM for the N1000MFD at a 20°F ΔT, per the submittal.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate