Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Peerless PureFire PF-140 vs PF-200

Verdict in brief

Both the Peerless PureFire PF-140 and the Peerless PureFire PF-200 belong to the Peerless Boilers PureFire line of condensing boilers. Published ratings: Peerless PureFire PF-140 at 35–140 MBH input, 131 MBH heating capacity and 95% AFUE; Peerless PureFire PF-200 at 42–199 MBH input, 185 MBH heating capacity and 95% AFUE. Peerless PureFire PF-200 lists 59 MBH more input than Peerless PureFire PF-140 (199 MBH against 140 MBH). Both list the same published AFUE of 95%. Peerless PureFire PF-200 lists 47 lb more shipping weight than Peerless PureFire PF-140 (165 lb against 118 lb).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Peerless PureFire PF-140 and Peerless PureFire PF-200
SpecificationPeerless PureFire PF-140Peerless PureFire PF-200
Input, minimum35 MBH42 MBH
Input, maximum140 MBH199 MBH
Heating capacity131 MBH185 MBH
Net water rating114 MBH161 MBH
Efficiency (AFUE)95 %95 %
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Approx. shipping weight118 lb165 lb
Dimensions (A × B × C)19-3/8" × 17-3/16" × 29-1/2"16-3/4" × 17-3/16" × 40-1/2"
Exhaust vent / air intake3"3"
Approved vent materialsPVC, CPVC, AL29-4C stainless or polypropylene (Category IV, positive pressure)PVC, CPVC, AL29-4C stainless or polypropylene (Category IV, positive pressure)
Supply/return connections1" NPT1" NPT
Gas connection1/2" NPT3/4" NPT
Electrical120 VAC, 60 Hz; max total service current to boiler 3.15 A120 VAC, 60 Hz; max total service current to boiler 22.67 A
ControlPureFire control with plain-English LCD displayPureFire control with plain-English LCD display
FuelNatural gas or LP gasNatural gas or LP gas

What actually separates them

Published ratings: the Peerless PureFire PF-140 is rated 35–140 MBH input, 131 MBH heating capacity and 95% AFUE; the Peerless PureFire PF-200 is rated 42–199 MBH input, 185 MBH heating capacity and 95% AFUE. Peerless PureFire PF-200 lists 59 MBH more input than Peerless PureFire PF-140 (199 MBH against 140 MBH). Both list the same published AFUE of 95%.

Peerless PureFire PF-200 lists 47 lb more shipping weight than Peerless PureFire PF-140 (165 lb against 118 lb). The dimensions differs: the Peerless PureFire PF-140 lists 19-3/8" × 17-3/16" × 29-1/2", while the Peerless PureFire PF-200 lists 16-3/4" × 17-3/16" × 40-1/2". The gas connection differs: the Peerless PureFire PF-140 lists 1/2" NPT, while the Peerless PureFire PF-200 lists 3/4" NPT. The electrical requirement differs: the Peerless PureFire PF-140 lists 120 VAC, 60 Hz; max total service current to boiler 3.15 A, while the Peerless PureFire PF-200 lists 120 VAC, 60 Hz; max total service current to boiler 22.67 A.

Both records print the same AFUE (95%), domestic-hot-water arrangement (Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater), venting (3") and approved vent materials (PVC, CPVC, AL29-4C stainless or polypropylene (Category IV, positive pressure)), per the cited sources.

Peerless Boilers

Peerless PureFire PF-140

CurrentCanadian status unknown
Input
35–140 MBH
Output (max)
AFUE
95 %

The Peerless PureFire PF-140 fires 35 to 140 MBH input with 131 MBH heating capacity and a 114 MBH net water rating at 95% AFUE — the top size in the small-cabinet group (PF-50/PF-80/PF-110/PF-140) — on the stainless-steel, sealed-combustion direct-vent condensing platform.

Natural gasPropaneHeating-only

Peerless Boilers

Peerless PureFire PF-200

CurrentCanadian status unknown
Input
42–199 MBH
Output (max)
AFUE
95 %

The Peerless PureFire PF-200 fires 42 to 199 MBH input with 185 MBH heating capacity and a 161 MBH net water rating at 95% AFUE — the first of the two large cabinet sizes (21 × 24 × 48 inch carton) with a 199 MBH cap — on the stainless-steel, sealed-combustion direct-vent condensing platform.

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The Peerless PureFire PF-200 lists 199 MBH, against 140 MBH on the Peerless PureFire PF-140, per the cited documentation.

Which model is more efficient?

Both list the same AFUE of 95%.

How much heavier is the Peerless PureFire PF-200?

It ships at 165 lb against 118 lb for the Peerless PureFire PF-140, per the cited sources.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate