Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Peerless Series TCII TCII-04 vs TCII-05

Verdict in brief

The Peerless Series TCII TCII-04 and Peerless Series TCII TCII-05 are both non-condensing boilers in the Peerless Boilers Series TCII line. Published ratings: Peerless Series TCII TCII-04 at 1,143 MBH gas input, 810 MBH net water rating and 81.4% gas thermal efficiency; Peerless Series TCII TCII-05 at 1,458 MBH gas input, 1,038 MBH net water rating and 81.9% gas thermal efficiency. Peerless Series TCII TCII-05 lists 315 MBH more gas input than Peerless Series TCII TCII-04 (1,458 MBH against 1,143 MBH). Peerless Series TCII TCII-05 carries the higher published gas thermal efficiency at 81.9%, against 81.4%.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Peerless Series TCII TCII-04 and Peerless Series TCII TCII-05
SpecificationPeerless Series TCII TCII-04Peerless Series TCII TCII-05
Net water rating810 MBH1,038 MBH
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
VentingForced draft with a power burnerForced draft with a power burner
FuelNatural gas or oil (combination gas/oil configurations)Natural gas or oil (combination gas/oil configurations)
Gas input1,143 MBH1,458 MBH
Oil input7.9 GPH10.2 GPH
Gross output931 MBH1,194 MBH
Net steam rating698 MBH896 MBH
Gas thermal efficiency81.4 %81.9 %
Oil thermal efficiency83.9 %84.4 %
ConstructionCast iron with flexible graphite port connectors and individual draw rodsCast iron with flexible graphite port connectors and individual draw rods

What actually separates them

Published ratings: the Peerless Series TCII TCII-04 is rated 1,143 MBH gas input, 810 MBH net water rating and 81.4% gas thermal efficiency; the Peerless Series TCII TCII-05 is rated 1,458 MBH gas input, 1,038 MBH net water rating and 81.9% gas thermal efficiency. Peerless Series TCII TCII-05 lists 315 MBH more gas input than Peerless Series TCII TCII-04 (1,458 MBH against 1,143 MBH). Peerless Series TCII TCII-05 carries the higher published gas thermal efficiency at 81.9%, against 81.4%.

Both records print the same domestic-hot-water arrangement (Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater), venting (Forced draft with a power burner), fuel (Natural gas or oil (combination gas/oil configurations)) and construction (Cast iron with flexible graphite port connectors and individual draw rods), per the cited sources.

CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-04 is a current commercial cast-iron steam or hot water boiler firing 1143 MBH gas (7.9 GPH oil) for 931 MBH gross output, a 698 MBH net steam rating (2908 sq ft) and a 810 MBH net water rating at 81.4% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE

The Peerless Series TCII TCII-05 is a current commercial cast-iron steam or hot water boiler firing 1458 MBH gas (10.2 GPH oil) for 1194 MBH gross output, a 896 MBH net steam rating (3733 sq ft) and a 1038 MBH net water rating at 81.9% gas thermal efficiency on a forced-draft power burner.

Natural gasHeating-only

Frequently asked questions

Which of the two has the higher maximum gas input?

The Peerless Series TCII TCII-05 lists 1,458 MBH, against 1,143 MBH on the Peerless Series TCII TCII-04, per the cited documentation.

Which model is more efficient?

The Peerless Series TCII TCII-05 carries the higher published gas thermal efficiency at 81.9%, against 81.4%.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate