Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Pennco 15B-060K vs 15B-120K

Verdict in brief

The 15B-060K and 15B-120K are both 84% AFUE Pennco 15B-K boilers. The 120K roughly doubles input (120 vs 59 MBH) and capacity, steps the flue from 4 to 6 inches, widens the cabinet from 13-3/8 to 16-1/4 inches and adds about 80 lb — the low-profile draft hood and removable burner tray are the same.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Pennco 15B-060K and Pennco 15B-120K
SpecificationPennco 15B-060KPennco 15B-120K
Input59 MBH120 MBH
Heating capacity50 MBH101 MBH
Net AHRI water rating43 MBH88 MBH
Efficiency (AFUE)84 %84 %
Flue diameter4"6"
Approx. shipping weight215 lb295 lb
Water content1.9 gal2.8 gal
Dimensions (width × height × depth)13-3/8" × 32-1/8" × 27-1/4"16-1/4" × 32-1/8" × 27-1/4"
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater

What actually separates them

Both boilers are chimney-vented cast-iron water boilers with dry-leg end sections, a low-profile draft diverter hood that reduces installation height by up to 30 inches, a removable burner tray for LP and high-altitude orifice changes, and a digital-display internal operating control. Their rows both print 84% AFUE: the 15B-060K at 59 MBH input with 50 MBH heating capacity and 43 MBH net AHRI, the 15B-120K at 120/101/88 MBH.

The flue and cabinet step together: 4-inch flue and 13-3/8-inch width on the 060K against 6-inch flue and 16-1/4-inch width on the 120K, with water content rising from 1.9 to 2.8 gallons and weight from 215 to 295 lb.

Both share the 32-1/8-inch height and 27-1/4-inch depth, 1-1/4-inch water tappings and 1/2-inch gas inlet. Choose by the calculated heat loss and connected radiation, not by the larger number on the sell sheet.

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The Pennco 15B-060K is the smallest 15B-K size with a 4-inch flue: 59 MBH input with 50 MBH heating capacity and a 43 MBH net AHRI water rating at 84% AFUE, chimney vented with a 4" flue.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
84 %

The Pennco 15B-120K is the mid-size 15B-K with a 6-inch flue: 120 MBH input with 101 MBH heating capacity and a 88 MBH net AHRI water rating at 84% AFUE, chimney vented with a 6" flue.

Natural gasPropaneHeating-only

Frequently asked questions

Which size has the larger flue?

The 15B-120K lists a 6-inch flue against the 15B-060K's 4-inch flue in the sell sheet ratings table.

Do both models use the same control?

Yes — both use the internal operating control with digital display, and a Resideo-control configuration is also documented for the 15B-K line on the official documents page.

Are both models 84% AFUE?

Yes — every printed 15B-K row, including the 060K and 120K, prints 84% AFUE.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate