Pennco
Pennco 15B-095K
- Input
- —
- Output (max)
- —
- AFUE
- 84 %
The Pennco 15B-095K is the second size, stepping to a 5-inch flue: 90.8 MBH input with 76.3 MBH heating capacity and a 66 MBH net AHRI water rating at 84% AFUE, chimney vented with a 5" flue.
Canada-wide gas boiler information · On-site service in Greater Vancouver, BC
Boilers.ca is a brand of ROMA Heating & Cooling · Licensed gas contractor LGA0202903
Comparison
Verdict in brief
Pennco 15B-095K and Pennco 15B-120K are two non-condensing boilers from the Pennco 15B-K line. Published ratings: Pennco 15B-095K at 90.8 MBH input, 76.3 MBH heating capacity and 84% AFUE; Pennco 15B-120K at 120 MBH input, 101 MBH heating capacity and 84% AFUE. Pennco 15B-120K lists 29.2 MBH more input than Pennco 15B-095K (120 MBH against 90.8 MBH). Both list the same published AFUE of 84%. Pennco 15B-120K lists 45 lb more shipping weight than Pennco 15B-095K (295 lb against 250 lb).
Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.
| Specification | Pennco 15B-095K | Pennco 15B-120K |
|---|---|---|
| Input | 90.8 MBH | 120 MBH |
| Heating capacity | 76.3 MBH | 101 MBH |
| Net AHRI water rating | 66 MBH | 88 MBH |
| Efficiency (AFUE) | 84 % | 84 % |
| Domestic hot water | Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater | Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater |
| Water content | 2.3 gal | 2.8 gal |
| Approx. shipping weight | 250 lb | 295 lb |
| Dimensions (width × height × depth) | 13-3/8" × 32-1/8" × 27-1/4" | 16-1/4" × 32-1/8" × 27-1/4" |
| Venting | Chimney vented with low-profile draft diverter hood | Chimney vented with low-profile draft diverter hood |
| Supply/return connections | 1-1/4" supply and return tappings | 1-1/4" supply and return tappings |
| Gas connection | 1/2" gas inlet | 1/2" gas inlet |
| Control | Internal operating control with digital display | Internal operating control with digital display |
| Fuel | Natural gas or propane | Natural gas or propane |
| Flue diameter | 5" | 6" |
Published ratings: the Pennco 15B-095K is rated 90.8 MBH input, 76.3 MBH heating capacity and 84% AFUE; the Pennco 15B-120K is rated 120 MBH input, 101 MBH heating capacity and 84% AFUE. Pennco 15B-120K lists 29.2 MBH more input than Pennco 15B-095K (120 MBH against 90.8 MBH). Both list the same published AFUE of 84%.
Pennco 15B-120K lists 45 lb more shipping weight than Pennco 15B-095K (295 lb against 250 lb). The boiler water content differs: the Pennco 15B-095K lists 2.3 gal, while the Pennco 15B-120K lists 2.8 gal. The dimensions differs: the Pennco 15B-095K lists 13-3/8" × 32-1/8" × 27-1/4", while the Pennco 15B-120K lists 16-1/4" × 32-1/8" × 27-1/4". The flue diameter differs: the Pennco 15B-095K lists 5", while the Pennco 15B-120K lists 6".
Both records print the same AFUE (84%), domestic-hot-water arrangement (Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater), venting (Chimney vented with low-profile draft diverter hood) and water connections (1-1/4" supply and return tappings), per the cited sources.
Pennco
The Pennco 15B-095K is the second size, stepping to a 5-inch flue: 90.8 MBH input with 76.3 MBH heating capacity and a 66 MBH net AHRI water rating at 84% AFUE, chimney vented with a 5" flue.
Pennco
The Pennco 15B-120K is the mid-size 15B-K with a 6-inch flue: 120 MBH input with 101 MBH heating capacity and a 88 MBH net AHRI water rating at 84% AFUE, chimney vented with a 6" flue.
The Pennco 15B-120K lists 120 MBH, against 90.8 MBH on the Pennco 15B-095K, per the cited documentation.
Both list the same AFUE of 84%.
It ships at 295 lb against 250 lb for the Pennco 15B-095K, per the cited sources.
A consultation includes a heat-loss review so the size is right the first time.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.