Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Pennco 1603HSID vs 1606HSID

Verdict in brief

The 1603HSID and 1606HSID are both Pennco 16 Series gas steam boilers. The 1606HSID roughly doubles input (187/175 vs 75/70 MBH natural gas/LP), net steam (115/107 vs 47/44 MBH) and steam square feet (479/446 vs 195/183), steps the flue from 5 to 7 inches and adds about 215 lb, while giving up 0.7 points of AFUE (82.0% vs 82.7%).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Pennco 1603HSID and Pennco 1606HSID
SpecificationPennco 1603HSIDPennco 1606HSID
Input (natural gas / LP)75 / 70 MBH187 / 175 MBH
Heating capacity (natural gas / LP)62 / 58 MBH153 / 143 MBH
Net steam (natural gas / LP)47 / 44 MBH115 / 107 MBH
Steam square feet (natural gas / LP)195 / 183 sq ft479 / 446 sq ft
Efficiency (AFUE)82.7 %82 %
Flue diameter5"7"
Approx. shipping weight297 lb512 lb
Dimensions (width × height × depth)11-1/4" × 36-3/8" × 26-1/2"21" × 36-3/8" × 26-1/2"
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater

What actually separates them

Both are cast-iron gas steam boilers with the same fully assembled control package: intermittent pilot control with continuous retry and 100% shut-off, electronic low-water cut-off with 3/4-inch probe, pressure limit control, steam pressure gauge, glass water level gauge, blocked vent spill switch and flame roll-out fuse link. Ratings are printed as natural-gas/LP pairs.

The capacity difference is the reason to choose between them: the 1603HSID prints 75/70 MBH input with 47/44 MBH net steam and 195/183 steam square feet at 82.7% AFUE, while the 1606HSID prints 187/175 MBH input with 115/107 MBH net steam and 479/446 square feet at 82.0%.

Physical planning follows: the flue steps from 5 to 7 inches, the cabinet widens from 11-1/4 to 21 inches at the same 36-3/8-inch height, and weight rises from 297 to 512 lb. Both use a 1.333 piping and pickup allowance for net steam and reduce ratings four percent per 1,000 feet above 2,000 feet.

CurrentCanadian status unknown
Input
Output (max)
AFUE
82.7 %

The Pennco 1603HSID is the smallest 16 Series size and the only 82.7% AFUE row: 75/70 MBH input (natural gas/LP) with 62/58 MBH heating capacity and a 47/44 MBH net steam rating at 82.7% AFUE.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
Output (max)
AFUE
82 %

The Pennco 1606HSID is the first size with a 7-inch flue: 187/175 MBH input (natural gas/LP) with 153/143 MBH heating capacity and a 115/107 MBH net steam rating at 82% AFUE.

Natural gasPropaneHeating-only

Frequently asked questions

Which model is more efficient?

The 1603HSID at 82.7% AFUE; the 1606HSID prints 82.0%, per the 16 Series sell sheet.

How much more steam does the 1606HSID produce?

Its AHRI net steam rating is 115/107 MBH (natural gas/LP) against 47/44 MBH on the 1603HSID, with steam square feet of 479/446 against 195/183.

Do both models share the same control package?

Yes — the standard equipment list is common across the 16 Series, including the electronic LWCO, pressure limit, spill switch and intermittent pilot control.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate