Pennco
Pennco 1605HSID
- Input
- —
- Output (max)
- —
- AFUE
- 82 %
The Pennco 1605HSID is the mid-size 16 Series model: 150/140 MBH input (natural gas/LP) with 122/114 MBH heating capacity and a 92/86 MBH net steam rating at 82% AFUE.
Canada-wide gas boiler information · On-site service in Greater Vancouver, BC
Boilers.ca is a brand of ROMA Heating & Cooling · Licensed gas contractor LGA0202903
Comparison
Verdict in brief
Both the Pennco 1605HSID and the Pennco 1606HSID belong to the Pennco 16 Series line of non-condensing boilers. Published ratings: Pennco 1605HSID at 150 / 140 MBH input, 122 / 114 MBH heating capacity and 82% AFUE; Pennco 1606HSID at 187 / 175 MBH input, 153 / 143 MBH heating capacity and 82% AFUE. The published input differs: Pennco 1605HSID lists 150 / 140 MBH, while Pennco 1606HSID lists 187 / 175 MBH. Both list the same published AFUE of 82%. Pennco 1606HSID lists 72 lb more shipping weight than Pennco 1605HSID (512 lb against 440 lb).
Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.
| Specification | Pennco 1605HSID | Pennco 1606HSID |
|---|---|---|
| Input (natural gas / LP) | 150 / 140 MBH | 187 / 175 MBH |
| Heating capacity (natural gas / LP) | 122 / 114 MBH | 153 / 143 MBH |
| Efficiency (AFUE) | 82 % | 82 % |
| Domestic hot water | Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater | Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater |
| Approx. shipping weight | 440 lb | 512 lb |
| Dimensions (width × height × depth) | 17-3/4" × 36-3/8" × 26-1/2" | 21" × 36-3/8" × 26-1/2" |
| Venting | Chimney vented with integral draft diverter | Chimney vented with integral draft diverter |
| Steam connections | 2" supply and 2" return | 2" supply and 2" return |
| Control | Intermittent pilot control with continuous retry and 100% shut-off | Intermittent pilot control with continuous retry and 100% shut-off |
| Fuel | Natural gas or propane (conversion kits available) | Natural gas or propane (conversion kits available) |
| Net steam (natural gas / LP) | 92 / 86 MBH | 115 / 107 MBH |
| Steam square feet (natural gas / LP) | 383 / 358 sq ft | 479 / 446 sq ft |
| Flue diameter | 6" | 7" |
Published ratings: the Pennco 1605HSID is rated 150 / 140 MBH input, 122 / 114 MBH heating capacity and 82% AFUE; the Pennco 1606HSID is rated 187 / 175 MBH input, 153 / 143 MBH heating capacity and 82% AFUE. The published input differs: Pennco 1605HSID lists 150 / 140 MBH, while Pennco 1606HSID lists 187 / 175 MBH. Both list the same published AFUE of 82%.
Pennco 1606HSID lists 72 lb more shipping weight than Pennco 1605HSID (512 lb against 440 lb). The dimensions differs: the Pennco 1605HSID lists 17-3/4" × 36-3/8" × 26-1/2", while the Pennco 1606HSID lists 21" × 36-3/8" × 26-1/2". The flue diameter differs: the Pennco 1605HSID lists 6", while the Pennco 1606HSID lists 7".
Both records print the same AFUE (82%), domestic-hot-water arrangement (Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater), venting (Chimney vented with integral draft diverter) and water connections (2" supply and 2" return), per the cited sources.
Pennco
The Pennco 1605HSID is the mid-size 16 Series model: 150/140 MBH input (natural gas/LP) with 122/114 MBH heating capacity and a 92/86 MBH net steam rating at 82% AFUE.
Pennco
The Pennco 1606HSID is the first size with a 7-inch flue: 187/175 MBH input (natural gas/LP) with 153/143 MBH heating capacity and a 115/107 MBH net steam rating at 82% AFUE.
The Pennco 1605HSID lists 150 / 140 MBH, while the Pennco 1606HSID lists 187 / 175 MBH, per the cited documentation.
Both list the same AFUE of 82%.
It ships at 512 lb against 440 lb for the Pennco 1605HSID, per the cited sources.
A consultation includes a heat-loss review so the size is right the first time.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.