Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Pennco 1605HSID vs Pennco 1606HSID

Verdict in brief

Both the Pennco 1605HSID and the Pennco 1606HSID belong to the Pennco 16 Series line of non-condensing boilers. Published ratings: Pennco 1605HSID at 150 / 140 MBH input, 122 / 114 MBH heating capacity and 82% AFUE; Pennco 1606HSID at 187 / 175 MBH input, 153 / 143 MBH heating capacity and 82% AFUE. The published input differs: Pennco 1605HSID lists 150 / 140 MBH, while Pennco 1606HSID lists 187 / 175 MBH. Both list the same published AFUE of 82%. Pennco 1606HSID lists 72 lb more shipping weight than Pennco 1605HSID (512 lb against 440 lb).

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Pennco 1605HSID and Pennco 1606HSID
SpecificationPennco 1605HSIDPennco 1606HSID
Input (natural gas / LP)150 / 140 MBH187 / 175 MBH
Heating capacity (natural gas / LP)122 / 114 MBH153 / 143 MBH
Efficiency (AFUE)82 %82 %
Domestic hot waterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heaterHeating-only boiler — domestic hot water comes from a separate indirect tank or water heater
Approx. shipping weight440 lb512 lb
Dimensions (width × height × depth)17-3/4" × 36-3/8" × 26-1/2"21" × 36-3/8" × 26-1/2"
VentingChimney vented with integral draft diverterChimney vented with integral draft diverter
Steam connections2" supply and 2" return2" supply and 2" return
ControlIntermittent pilot control with continuous retry and 100% shut-offIntermittent pilot control with continuous retry and 100% shut-off
FuelNatural gas or propane (conversion kits available)Natural gas or propane (conversion kits available)
Net steam (natural gas / LP)92 / 86 MBH115 / 107 MBH
Steam square feet (natural gas / LP)383 / 358 sq ft479 / 446 sq ft
Flue diameter6"7"

What actually separates them

Published ratings: the Pennco 1605HSID is rated 150 / 140 MBH input, 122 / 114 MBH heating capacity and 82% AFUE; the Pennco 1606HSID is rated 187 / 175 MBH input, 153 / 143 MBH heating capacity and 82% AFUE. The published input differs: Pennco 1605HSID lists 150 / 140 MBH, while Pennco 1606HSID lists 187 / 175 MBH. Both list the same published AFUE of 82%.

Pennco 1606HSID lists 72 lb more shipping weight than Pennco 1605HSID (512 lb against 440 lb). The dimensions differs: the Pennco 1605HSID lists 17-3/4" × 36-3/8" × 26-1/2", while the Pennco 1606HSID lists 21" × 36-3/8" × 26-1/2". The flue diameter differs: the Pennco 1605HSID lists 6", while the Pennco 1606HSID lists 7".

Both records print the same AFUE (82%), domestic-hot-water arrangement (Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater), venting (Chimney vented with integral draft diverter) and water connections (2" supply and 2" return), per the cited sources.

CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The Pennco 1605HSID is the mid-size 16 Series model: 150/140 MBH input (natural gas/LP) with 122/114 MBH heating capacity and a 92/86 MBH net steam rating at 82% AFUE.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
—
AFUE
82 %

The Pennco 1606HSID is the first size with a 7-inch flue: 187/175 MBH input (natural gas/LP) with 153/143 MBH heating capacity and a 115/107 MBH net steam rating at 82% AFUE.

Natural gasPropaneHeating-only

Frequently asked questions

How do the published input figures compare?

The Pennco 1605HSID lists 150 / 140 MBH, while the Pennco 1606HSID lists 187 / 175 MBH, per the cited documentation.

Which model is more efficient?

Both list the same AFUE of 82%.

How much heavier is the Pennco 1606HSID?

It ships at 512 lb against 440 lb for the Pennco 1605HSID, per the cited sources.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate