- Input
- —
- Output (max)
- 335 MBH
- AFUE
- —
The Raypak Delta Limited H4-399B is an indoor non-condensing copper-fin commercial hydronic boiler rated 399 MBTUH input and 335 MBTUH Type H output at 84% thermal efficiency, with 1-stage firing and a 6 in flue.
Canada-wide gas boiler information · On-site service in Greater Vancouver, BC
Boilers.ca is a brand of ROMA Heating & Cooling · Licensed gas contractor LGA0202903
Comparison
Verdict in brief
The Delta Limited H3-499B adds 101 MBTUH of input and 85 MBTUH of output over the Delta Limited H4-399B on the same Delta Limited platform. The 399B is the only on-off (H4) size in the line; the 499B starts the 2-stage (H3) range with 500 MBTUH input and a 1-1/4 in gas connection.
Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.
| Specification | Raypak Delta Limited H4-399B | Raypak Delta Limited H3-499B |
|---|---|---|
| Input | 399 MBH | 500 MBH |
| Output | 335 MBH | 420 MBH |
| AHRI thermal efficiency | 84 % | 84 % |
| Firing stages | 1 firing stage | 2 firing stages |
| Water connection | 2" NPT | 2" NPT |
| Flue outlet | 6 in | 6 in |
| Weight | 445 lb | 545 lb |
The H4-399B is rated 399 MBTUH input and 335 MBTUH output with 1:1 turndown; the H3-499B is rated 500 MBTUH input and 420 MBTUH output with 2:1 turndown. Both models carry the same published efficiency figure, so capacity is the variable rather than efficiency.
The 399B is the only on-off (H4) size in the line; the 499B starts the 2-stage (H3) range with 500 MBTUH input and a 1-1/4 in gas connection. Both share the same 90 gpm maximum water flow, so the step up does not enlarge the pump or piping envelope. Shipping or operating weight moves from 445 lb to 545 lb, which matters for rigging and floor loading.
Both sizes are documented in the same official Raypak submittal for the Delta Limited family, so the decision is a heat-loss and plant-layout question rather than a documentation difference: size to the calculated design-day load, then check flow, connection and venting dimensions against the submittal for the exact model.
The Raypak Delta Limited H4-399B is an indoor non-condensing copper-fin commercial hydronic boiler rated 399 MBTUH input and 335 MBTUH Type H output at 84% thermal efficiency, with 1-stage firing and a 6 in flue.
The Raypak Delta Limited H3-499B is an indoor non-condensing copper-fin commercial hydronic boiler rated 500 MBTUH input and 420 MBTUH Type H output at 84% thermal efficiency, with 2-stage firing and a 6 in flue.
The I&O manual's key reads H for hydronic and the following digit for firing mode: 4 = on-off and 3 = 2-stage.
Yes — both use a 6 in flue connection per the 242015 submittal.
A consultation includes a heat-loss review so the size is right the first time.