RBI Futera III 1750 vs Futera III 2000

Verdict in brief

The Futera III 1750 and 2000 share the same 47-3/16" × 29-1/8" cabinet, 1-1/2" gas and 2-1/2" water connections and identical 12"/10"/10" flue options; the 2000 adds 250 MBH of input and about 213 MBH of output, grows 4-1/2" taller and ships 172 lb heavier.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of RBI Futera III 1750 and RBI Futera III 2000
SpecificationRBI Futera III 1750RBI Futera III 2000
Input, maximum1,750 MBH2,000 MBH
Boiler output1,491 MBH1,704 MBH
Efficiency (AHRI boiler)85.6 %85.6 %
Turndown4:14:1
Gas connection1 1/2"1 1/2"
Water connection2 1/2"2 1/2"
Flue ventCat I 12" / Cat II 10" / Cat IV 10"Cat I 12" / Cat II 10" / Cat IV 10"
Air intake12"12"
Unit width29.125 in29.125 in
Unit depth47.188 in47.188 in
Unit height64.5 in69 in
Shipping weight928 lb1,100 lb

What actually separates them

These are the top two rows of the Futera III ratings table: 1,750 MBH input / 1,491 MBH output for the MB/MW 1750 and 2,000 MBH / 1,704 MBH for the MB/MW 2000. Depth and width are identical; only the height changes, from 64-1/2" to 69" (the source prints 1938 mm for the 1750 height row).

All connections and venting options are shared — 1-1/2" gas, 2-1/2" water, 12" air intake and Category I 12" / Category II 10" / Category IV 10" flues — so near-boiler piping and vent design carry over between the two.

Shipping weight is the practical difference on site: 928 lb for the 1750 against 1,100 lb for the 2000. Both remain 85.6% AHRI Boiler Efficiency with 4:1 turndown on HEATNET 3.0.

CurrentCanadian status unknown
Input
Output (max)
1,491 MBH
AFUE

The RBI Futera III 1750 is a gas-fired copper-fin commercial boiler rated 1750 MBH input and 1491 MBH boiler output in RBI's published ratings table, with 4:1 full modulation, Category I/II/IV venting and a 928 lb shipping weight.

Natural gasHeating-only
CurrentCanadian status unknown
Input
Output (max)
1,704 MBH
AFUE

The RBI Futera III 2000 is a gas-fired copper-fin commercial boiler rated 2000 MBH input and 1704 MBH boiler output in RBI's published ratings table, with 4:1 full modulation, Category I/II/IV venting and a 1100 lb shipping weight.

Natural gasHeating-only

Frequently asked questions

Are the vent sizes the same?

Yes — both rows print Category I 12", Category II 10" and Category IV 10" with a 12" air intake.

Which is heavier?

The MB/MW 2000 at 1,100 lb shipping against 928 lb for the MB/MW 1750, per RBI's ratings table.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.