Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

RBI Futera XLF 5000 vs Futera XLF 6000

Verdict in brief

The Futera XLF 5000 and 6000 are different physical platforms: the 5000 keeps the slim 31-1/8" × 29-1/8" cabinet at 78" high with a 14"/14"/12" flue set and 2" gas, while the 6000 moves to a 68-3/8" × 55-1/3" cabinet at 59-15/16" high with 12"/12"/12" flues, a 2-1/2" gas connection and no printed LP connection — adding about 989 MBH of output and 726 lb of shipping weight.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of RBI Futera XLF 5000 and RBI Futera XLF 6000
SpecificationRBI Futera XLF 5000RBI Futera XLF 6000
Input, maximum5,000 MBH6,000 MBH
Boiler output4,255 MBH5,244 MBH
Efficiency (AHRI boiler)85.9 %85.9 %
Turndown5:15:1
Gas connection (natural gas)2"2 1/2"
Gas connection (LP)1 1/2"not printed
Water connection4"4"
Flue ventCat I 14" / Cat II 14" / Cat IV 12"Cat I 12" / Cat II 12" / Cat IV 12"
Unit width29.125 in55.333 in
Unit depth31.125 in68.375 in
Unit height78 in59.938 in
Shipping weight2,000 lb2,726 lb

What actually separates them

The 6000 is the first XLF row printed as MB (boiler) only rather than MB/MW, and it is the first to leave the slim cabinet: depth jumps from 31-1/8" to 68-3/8", width from 29-1/8" to 55-1/3", height drops from 78" to 59-15/16", and shipping weight rises from 2,000 lb to 2,726 lb.

Output rises from 4,255 MBH to 5,244 MBH at inputs of 5,000 and 6,000 MBH. Gas connection steps from 2" to 2-1/2"; the LP column is blank on the 6000 row, while the 5000 prints 1-1/2" LP. Water connection stays 4" on both.

Flue options change with the platform: 14"/14"/12" (Cat I/II/IV) on the 5000 against 12"/12"/12" on the 6000. Both remain 85.9% AHRI Boiler Efficiency with 5:1 turndown; the mechanical-room layout is the deciding factor as much as capacity.

CurrentCanadian status unknown
Input
—
Output (max)
4,255 MBH
AFUE
—

The RBI Futera XLF 5000 is a gas-fired copper-fin commercial boiler rated 5000 MBH input and 4255 MBH boiler output in RBI's published ratings table, with 5:1 full modulation, Category I/II/IV venting and a 2000 lb shipping weight.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
5,244 MBH
AFUE
—

The RBI Futera XLF 6000 is a gas-fired copper-fin commercial boiler rated 6000 MBH input and 5244 MBH boiler output in RBI's published ratings table, with 5:1 full modulation, Category I/II/IV venting and a 2726 lb shipping weight.

Natural gasHeating-only

Frequently asked questions

Do the 5000 and 6000 share a cabinet?

No — the 5000 uses the slim 31-1/8" × 29-1/8" × 78" cabinet; the 6000 moves to 68-3/8" × 55-1/3" × 59-15/16".

Does the 6000 print an LP connection?

No — the LP column is blank on the MB 6000 row; the MB 5000 prints a 1-1/2" LP connection.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate