Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

RBI Infinite Energy² 750 vs Infinite Energy² 1000

Verdict in brief

The Infinite Energy² 750 and 1000 share the same 35.3" × 23.6" × 71.5" cabinet, 6" flue and air intake, 1-1/4" gas and 2-1/2" water connections; the 1000 adds 250 MBH of input and about 241 MBH of output at 73 lb more shipping weight.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of RBI Infinite Energy² 750 and RBI Infinite Energy² 1000
SpecificationRBI Infinite Energy² 750RBI Infinite Energy² 1000
Input, maximum750 MBH1,000 MBH
Boiler output711 MBH952 MBH
Efficiency (AHRI boiler)95.2 %95.2 %
Turndownup to 20:1up to 20:1
Gas connection1 1/4"1 1/4"
Water connection2 1/2"2 1/2"
Flue vent6"6"
Air intake6"6"
Unit width23.6 in23.6 in
Unit depth35.3 in35.3 in
Unit height71.5 in71.5 in
Shipping weight539 lb612 lb

What actually separates them

RBI prints 750 MBH input / 711 MBH output for the IB/IW 750 and 1,000 MBH / 952 MBH for the IB/IW 1000 — the top of the IE² line. Both use the taller 71.5" cabinet and 6" venting.

Because the cabinet, connections and venting are identical, the decision is purely load-based: shipping weight rises from 539 lb to 612 lb, and the larger unit's minimum fire is proportionally higher.

Both remain 95.2% AHRI Boiler Efficiency with up to 20:1 turndown, cascade control for up to eight units and PVC/CPVC/polypropylene/stainless vent approval.

CurrentCanadian status unknown
Input
—
Output (max)
711 MBH
AFUE
—

The RBI Infinite Energy² 750 is a gas-fired stainless-steel condensing commercial boiler rated 750 MBH input and 711 MBH boiler output in RBI's published ratings table, with full modulation up to 20:1 and a 539 lb shipping weight.

Natural gasHeating-only
CurrentCanadian status unknown
Input
—
Output (max)
952 MBH
AFUE
—

The RBI Infinite Energy² 1000 is a gas-fired stainless-steel condensing commercial boiler rated 1000 MBH input and 952 MBH boiler output in RBI's published ratings table, with full modulation up to 20:1 and a 612 lb shipping weight.

Natural gasHeating-only

Frequently asked questions

How tall are these units?

Both print 71.5" high × 35.3" deep × 23.6" wide in RBI's ratings table.

What is the maximum output of the IE² 1000?

952 MBH boiler output at 1,000 MBH input, per RBI's ratings table.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate