Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Rinnai Q85SN vs Q130SN

Verdict in brief

The Q85SN and Q130SN are heating-only Q-Series boilers that share the same 15.2 in depth and 31.4 in height: the Q85SN prints an 85,000 BTU central-heating capacity at 110 lb, the Q130SN 130,000 BTU at 117 lb, with minimum-input bullets of 17,000 and 26,000 BTU. Both print the truncated "N (maximum)" bullet.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Rinnai Q85SN and Rinnai Q130SN
SpecificationRinnai Q85SNRinnai Q130SN
Minimum input (hero bullet)17 MBH26 MBH
Central heating capacity85 MBH130 MBH
Product weight110 lb117 lb
Product width19.7 in19.7 in

What actually separates them

The Q85SN and Q130SN are the smaller of the three Q-Series heating-only boilers. Their pages print minimum-input hero bullets of 17,000 and 26,000 BTU and central-heating capacities of 85,000 and 130,000 BTU, so the step between them is 45,000 BTU of heating capacity.

Both are heating-only: the pages print no DHW flow row and no cold-inlet/hot-outlet connections, unlike the Q175CN combi. Physically the Q130SN is 7 lb heavier (117 against 110 lb) and 0.2 in wider (19.7 against 19.7 in — both print the same 19.7 in width; the difference is weight). The maximum-input bullets on both pages are the truncated "N (maximum)" common to every Q solo page, so no numeric maximum is recorded.

The Q-Series pages print Residential ENERGY STAR "Yes" and SCAQMD Ultra Low NOx rows, a 3/4" MNPT gas connection and no AFUE or venting figures. The line is recorded as legacy: the pages are live but the current condensing-boilers navigation lists only the I-SERIES+.

DiscontinuedHistorically in Canada
Input
17–N (maximum) — page print bug undefined
Output (max)
AFUE

The Rinnai Q85SN is a heating-only model in the Q-Series: a condensing boiler with a 85,000 BTU central-heating capacity and no domestic hot water production, at 110 lb.

Natural gasHeating-only
DiscontinuedHistorically in Canada
Input
26–N (maximum) — page print bug undefined
Output (max)
AFUE

The Rinnai Q130SN is a heating-only model in the Q-Series: a condensing boiler with a 130,000 BTU central-heating capacity and no domestic hot water production, at 117 lb.

Natural gasHeating-only

Frequently asked questions

What is the difference between the Q85SN and Q130SN?

The central-heating capacity: 85,000 against 130,000 BTU, with minimum inputs of 17,000 and 26,000 BTU and weights of 110 and 117 lb. Both are heating-only with the same cabinet depth and height.

Do the Q85SN and Q130SN make hot water?

No. Both are heating-only Q-Series boilers; domestic hot water comes from a separate tank or heater. The Q175CN is the combi in this line.

Why do both pages print 'N (maximum)'?

That is a page-print bug on every Q-Series solo page: the maximum-input hero bullet is truncated to 'N (maximum)'. Boilers.ca records the bullet as printed rather than reading 'N' as 'no maximum'.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate