Skip to content
Boilers.caby ROMA Heating & Cooling

Comparison

Takagi T-D2-IN-N vs T-D2-OS-N

Verdict in brief

The T-D2-IN-N and T-D2-OS-N are the indoor and outdoor versions of the same non-condensing tankless water heater: both fire 11,000 to 199,000 BTU/h at 0.80 thermal efficiency with 10 GPM, 45 lb and the same 20-1/4 × 13-3/4 × 9-1/2 in cabinet. The indoor model vents on 4" Category III to 50 ft; the outdoor model has an integral exhaust vent.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Takagi T-D2-IN-N and Takagi T-D2-OS-N
SpecificationTakagi T-D2-IN-NTakagi T-D2-OS-N
Input, minimum11,000 BTU/h11,000 BTU/h
Input, maximum199,000 BTU/h199,000 BTU/h
Thermal efficiency0.8 %0.8 %
Maximum flow rate10 GPM10 GPM
Weight45 lb45 lb
InstallationIndoorOutdoor
Venting4" Category III to 50 equivalent ft; optional direct-vent conversion with 3" intakeIntegral exhaust vent on the front of the outdoor unit

What actually separates them

The T-D2-IN-N and T-D2-OS-N share the same rating row on Takagi's specification sheet TRGSS01613: 11,000 to 199,000 BTU/h input, 0.80 thermal efficiency, 10 GPM maximum flow, 3/4" NPT water and gas connections, 45 lb weight and a 20-1/4 × 13-3/4 × 9-1/2 in cabinet. Both are natural-gas models (propane -P versions of each also exist).

The difference is installation and venting: the IN model installs indoors and vents with 4" Category III pipe to 50 equivalent ft, with an optional direct-vent conversion kit using a 3" intake, while the OS model installs outdoors with an integral exhaust vent on the front of the unit. Both are non-condensing tankless water heaters, not boilers.

Choosing between them is a site decision — indoor placement needs vent runs, condensate management is not a factor on a non-condensing unit, and outdoor placement needs freeze protection and clearance planning per the installation manual. Ratings and capacity are identical.

CurrentCanadian status unknown
Input
11000–199000 BTU/h
Output (max)
—
AFUE
—

The Takagi T-D2-IN-N is a non-condensing tankless water heater — a DHW-only appliance, not a boiler — firing 11,000 to 199,000 BTU/h on natural gas with 0.8% thermal efficiency and up to 10 GPM.

Natural gasDHW-only (tankless)
CurrentCanadian status unknown
Input
11000–199000 BTU/h
Output (max)
—
AFUE
—

The Takagi T-D2-OS-N is a non-condensing tankless water heater — a DHW-only appliance, not a boiler — firing 11,000 to 199,000 BTU/h on natural gas with 0.8% thermal efficiency and up to 10 GPM.

Natural gasDHW-only (tankless)

Frequently asked questions

Do the indoor and outdoor T-D2 models differ in capacity?

No. Both print 11,000–199,000 BTU/h, 0.80 thermal efficiency and 10 GPM maximum flow; only the venting and installation configuration differ.

Are T-D2 models boilers?

No. The T-D2 Series is a non-condensing tankless water heater line. Takagi's catalogue contains no boiler line.

What venting does the indoor T-D2 need?

The specification sheet prints 4" Category III venting to 50 equivalent ft with 5 elbows maximum (90° elbows = 5 ft equivalent), and an optional direct-vent conversion kit using a 3" intake pipe.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate