Triangle Tube Phase III TR-20 vs TR-30

Verdict in brief

The Phase III TR-20 and TR-30 are adjacent TR tanks: 20 versus 30 gallons domestic capacity, 80 versus 87 MBH boiler heating capacity and first-hour flows of 125 versus 140 gal/hr. Both use 3/4" domestic and 1" boiler connections with a 3/4 ft boiler-side head loss.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Triangle Tube Phase III TR-20 and Triangle Tube Phase III TR-30
SpecificationTriangle Tube Phase III TR-20Triangle Tube Phase III TR-30
Domestic water capacity20 gal30 gal
Boiler water volume8 gal9 gal
Heating surface12 sq ft15 sq ft
Boiler heating capacity80 MBH87 MBH
First hour flow125 gal/hr140 gal/hr
Continuous flow110 gal/hr115 gal/hr
Minimum circulator flow5 GPM6 GPM
Domestic connection3/4"3/4"
Boiler connection1"1"
Empty weight110 lb165 lb

What actually separates them

The archived manual lists the TR-20 at 20 gallons domestic capacity, 8 gallons boiler water, 12 sq ft heating surface, 80 MBH boiler heating capacity, 35 gal/10 min peak flow, 125 gal/hr first-hour flow, 110 gal/hr continuous flow and a 5 gpm minimum circulator flow.

The TR-30 lists 30 gallons domestic, 9 gallons boiler water, 15 sq ft surface, 87 MBH coil, 45 gal/10 min peak, 140 gal/hr first hour, 115 gal/hr continuous and a 6 gpm minimum circulator flow.

Both print 3/4" domestic and 1" boiler connections, a 3/4 ft boiler-side head loss and vertical-only installation; the TR-30 adds 10 gallons of storage and 55 lb of empty weight.

DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Triangle Tube Phase III TR-20 is a discontinued 20-gallon indirect water heater with 8 gallons of boiler water, 12 sq ft of heating surface and a printed first-hour flow of 125 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.

Natural gasPropaneDHW-only (tankless)
DiscontinuedHistorically in Canada
Input
Output (max)
AFUE

The Triangle Tube Phase III TR-30 is a discontinued 30-gallon indirect water heater with 9 gallons of boiler water, 15 sq ft of heating surface and a printed first-hour flow of 140 gallons at 50°F inlet / 140°F outlet / 200°F boiler supply.

Natural gasPropaneDHW-only (tankless)

Frequently asked questions

What is the capacity difference between the TR-20 and TR-30?

The archived manual prints 20 gallons for the TR-20 and 30 gallons for the TR-30, with boiler water volumes of 8 and 9 gallons.

Do the two tanks need the same circulator flow?

No — the printed minimum circulator flows are 5 gpm for the TR-20 and 6 gpm for the TR-30.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.