Utica MGB-060K vs MGB-095K

Verdict in brief

The MGB-060K and MGB-095K are adjacent sizes in the current MGB-K cast-iron water line — both non-condensing atmospheric boilers at 84% AFUE with 1¼" NPT water connections and a Hydrolevel control with built-in LWCO. The MGB-095K fires 90.8 MBH against 59 MBH, printing 76.3 MBH of heating capacity (50) and a 66 MBH net AHRI water rating (43); the flue steps from 4" to 5" and they share the 13⅜ × 32⅛ × 27¼ in cabinet, with 3 burners against 2 and a shipping weight of 250 lb against 215 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Utica MGB-060K and Utica MGB-095K
SpecificationUtica MGB-060KUtica MGB-095K
Input59 MBH90.8 MBH
Heating capacity50 MBH76.3 MBH
Net AHRI water rating43 MBH66 MBH
AFUE84 %84 %
Boiler water content1.9 gal2.3 gal
Flue connection4"5"
Burners23
Dimensions (W x H x D)13⅜ × 32⅛ × 27¼13⅜ × 32⅛ × 27¼
Shipping weight215 lb250 lb

What actually separates them

Both models are MGB-K cast-iron water boilers at 84% AFUE — a non-condensing, atmospheric chimney-vented design with an integral low-profile draft hood, motorized vent damper, dry-leg cast-iron heat exchanger and a Hydrolevel control with built-in low water cut-off. Neither modulates: input is fixed.

The brochure table prints 59 MBH input with 50 MBH heating capacity and a 43 MBH net AHRI water rating on the MGB-060K, against 90.8 MBH, 76.3 MBH and 66 MBH on the MGB-095K. Boiler water content rises from 1.9 to 2.3 gal and burner count from 2 to 3.

Installation details move with size: the flue steps from 4" to 5", both take ½" NPT gas, and they share the 13⅜ × 32⅛ × 27¼ in cabinet; shipping weight rises from 215 to 250 lb. A licensed heat-loss calculation should decide between the two — extra capacity beyond the design load only shortens run times in a fixed-input boiler.

Utica Boilers

Utica MGB-060K

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
84 %

The Utica MGB-060K is a size in the current MGB-K cast-iron water line: 59 MBH fixed input, 50 MBH heating capacity, a 43 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 4" flue and 2 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Utica Boilers

Utica MGB-095K

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
84 %

The Utica MGB-095K is a size in the current MGB-K cast-iron water line: 90.8 MBH fixed input, 76.3 MBH heating capacity, a 66 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 5" flue and 3 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Frequently asked questions

What does the MGB-095K add over the MGB-060K?

90.8 MBH input against 59 MBH, 76.3 MBH heating capacity against 50 MBH, and a 66 MBH net AHRI water rating against 43 MBH, per the official MGB-K brochure table.

Are both boilers condensing?

No — every MGB-K is a non-condensing cast-iron boiler at 84% AFUE with atmospheric chimney venting, an integral draft hood and a motorized vent damper.

Which size should a project choose?

Size from a licensed heat-loss calculation: the MGB-060K suits loads that fit its 50 MBH heating capacity, while the MGB-095K covers loads approaching 76.3 MBH. Neither modulates, so oversizing shows up as shorter run cycles.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate