Utica MGB-095K vs MGB-120K

Verdict in brief

The MGB-095K and MGB-120K are adjacent sizes in the current MGB-K cast-iron water line — both non-condensing atmospheric boilers at 84% AFUE with 1¼" NPT water connections and a Hydrolevel control with built-in LWCO. The MGB-120K fires 120 MBH against 90.8 MBH, printing 101 MBH of heating capacity (76.3) and a 88 MBH net AHRI water rating (66); the flue steps from 5" to 6" and the cabinet changes from 13⅜ × 32⅛ × 27¼ in to 16¼ × 32⅛ × 27¼ in, with 4 burners against 3 and a shipping weight of 295 lb against 250 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Utica MGB-095K and Utica MGB-120K
SpecificationUtica MGB-095KUtica MGB-120K
Input90.8 MBH120 MBH
Heating capacity76.3 MBH101 MBH
Net AHRI water rating66 MBH88 MBH
AFUE84 %84 %
Boiler water content2.3 gal2.8 gal
Flue connection5"6"
Burners34
Dimensions (W x H x D)13⅜ × 32⅛ × 27¼16¼ × 32⅛ × 27¼
Shipping weight250 lb295 lb

What actually separates them

Both models are MGB-K cast-iron water boilers at 84% AFUE — a non-condensing, atmospheric chimney-vented design with an integral low-profile draft hood, motorized vent damper, dry-leg cast-iron heat exchanger and a Hydrolevel control with built-in low water cut-off. Neither modulates: input is fixed.

The brochure table prints 90.8 MBH input with 76.3 MBH heating capacity and a 66 MBH net AHRI water rating on the MGB-095K, against 120 MBH, 101 MBH and 88 MBH on the MGB-120K. Boiler water content rises from 2.3 to 2.8 gal and burner count from 3 to 4.

Installation details move with size: the flue steps from 5" to 6", both take ½" NPT gas, and the cabinet changes from 13⅜ × 32⅛ × 27¼ in to 16¼ × 32⅛ × 27¼ in; shipping weight rises from 250 to 295 lb. A licensed heat-loss calculation should decide between the two — extra capacity beyond the design load only shortens run times in a fixed-input boiler.

Utica Boilers

Utica MGB-095K

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
84 %

The Utica MGB-095K is a size in the current MGB-K cast-iron water line: 90.8 MBH fixed input, 76.3 MBH heating capacity, a 66 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 5" flue and 3 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Utica Boilers

Utica MGB-120K

CurrentSold in Canada
Input
—
Output (max)
—
AFUE
84 %

The Utica MGB-120K is a size in the current MGB-K cast-iron water line: 120 MBH fixed input, 101 MBH heating capacity, a 88 MBH net AHRI water rating and 84% AFUE, with atmospheric chimney venting, a 6" flue and 4 burners. Its card carries the official 'Current' and 'Available in Canada' tags.

Natural gasPropaneHeating-only

Frequently asked questions

What does the MGB-120K add over the MGB-095K?

120 MBH input against 90.8 MBH, 101 MBH heating capacity against 76.3 MBH, and a 88 MBH net AHRI water rating against 66 MBH, per the official MGB-K brochure table.

Are both boilers condensing?

No — every MGB-K is a non-condensing cast-iron boiler at 84% AFUE with atmospheric chimney venting, an integral draft hood and a motorized vent damper.

Which size should a project choose?

Size from a licensed heat-loss calculation: the MGB-095K suits loads that fit its 76.3 MBH heating capacity, while the MGB-120K covers loads approaching 101 MBH. Neither modulates, so oversizing shows up as shorter run cycles.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate