Utica SVB-3 vs SVB-4

Verdict in brief

The SVB-3 and SVB-4 are adjacent sizes in the current SVB Series 4 induced-draft cast-iron water line — both non-condensing boilers with a Honeywell high-limit/electronic-ignition control and chimney or sidewall venting. The SVB-4 fires 112.5 MBH against 75 MBH, printing 95 MBH of heating capacity (63) and a 82 MBH net AHRI water rating (55); both allow a 3" sidewall vent, with boiler water rising from 3 to 4.25 gal and shipping weight from 265 to 322 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Utica SVB-3 and Utica SVB-4
SpecificationUtica SVB-3Utica SVB-4
Input75 MBH112.5 MBH
Heating capacity63 MBH95 MBH
Net AHRI water rating55 MBH82 MBH
AFUE84 %84 %
Vent — chimney4"4"
Vent — sidewall3"3"
Boiler water content3 gal4.25 gal
Dimensions (W x H x D)14¼ × 29 × 23¼17½ × 29 × 23¼
Shipping weight265 lb322 lb

What actually separates them

Both models are SVB Series 4 cast-iron water boilers — non-condensing with fixed input, an induced-draft fan that allows chimney or sidewall exhaust, cast-iron push nipples, titanium composite burners and a recessed Honeywell high-limit/electronic-ignition control with digital temperature display and diagnostics.

The sell-sheet table prints 75 MBH input with 63 MBH heating capacity and a 55 MBH net AHRI water rating on the SVB-3, against 112.5 MBH, 95 MBH and 82 MBH on the SVB-4; the SVB-3 carries the line's top rating of 84.4% AFUE against 84% on the SVB-4.

Venting and footprint scale with the size: chimney vent is 4" on both, both allow a 3" sidewall vent, and the cabinet grows from 14¼ × 29 × 23¼ in to 17½ × 29 × 23¼ in as water content rises from 3 to 4.25 gal and weight from 265 to 322 lb. A heat-loss calculation decides between them; installation belongs with a licensed contractor.

Utica Boilers

Utica SVB-3

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Utica SVB-3 is a size in the current SVB Series 4 cast-iron water line: 75 MBH fixed input, 63 MBH heating capacity, a 55 MBH net AHRI water rating and 84% AFUE, with induced-draft chimney (4") or sidewall (3") venting. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Utica Boilers

Utica SVB-4

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Utica SVB-4 is a size in the current SVB Series 4 cast-iron water line: 112.5 MBH fixed input, 95 MBH heating capacity, a 82 MBH net AHRI water rating and 84% AFUE, with induced-draft chimney (4") or sidewall (3") venting. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Frequently asked questions

What does the SVB-4 add over the SVB-3?

112.5 MBH input against 75 MBH, 95 MBH heating capacity against 63 MBH, and a 82 MBH net AHRI water rating against 55 MBH, per the official SVB Series 4 sell sheet.

Can both vent through a sidewall?

Yes — the induced-draft fan allows chimney or sidewall exhaust: SVB-3 uses 4" chimney and 3" sidewall; SVB-4 uses 4" chimney and 3" sidewall.

Are both boilers condensing?

No — every SVB Series 4 is a non-condensing cast-iron boiler with an induced-draft fan and chimney or sidewall exhaust.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification