Verdict in brief

The SVB-5 and SVB-6 are adjacent sizes in the current SVB Series 4 induced-draft cast-iron water line — both non-condensing boilers with a Honeywell high-limit/electronic-ignition control and chimney or sidewall venting. The SVB-6 fires 187.5 MBH against 150 MBH, printing 158 MBH of heating capacity (127) and a 135 MBH net AHRI water rating (109); the sidewall vent steps from 3" to 4", with boiler water rising from 5.5 to 6.75 gal and shipping weight from 370 to 431 lb.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Utica SVB-5 and Utica SVB-6
SpecificationUtica SVB-5Utica SVB-6
Input150 MBH187.5 MBH
Heating capacity127 MBH158 MBH
Net AHRI water rating109 MBH135 MBH
AFUE84 %84 %
Vent — chimney4"4"
Vent — sidewall3"4"
Boiler water content5.5 gal6.75 gal
Dimensions (W x H x D)20¾ × 29 × 23¼24 × 29 × 23¼
Shipping weight370 lb431 lb

What actually separates them

Both models are SVB Series 4 cast-iron water boilers — non-condensing with fixed input, an induced-draft fan that allows chimney or sidewall exhaust, cast-iron push nipples, titanium composite burners and a recessed Honeywell high-limit/electronic-ignition control with digital temperature display and diagnostics.

The sell-sheet table prints 150 MBH input with 127 MBH heating capacity and a 109 MBH net AHRI water rating on the SVB-5, against 187.5 MBH, 158 MBH and 135 MBH on the SVB-6; the SVB-5 carries the line's top rating of 84.4% AFUE against 84% on the SVB-6.

Venting and footprint scale with the size: chimney vent is 4" on both, the sidewall vent steps from 3" to 4", and the cabinet grows from 20¾ × 29 × 23¼ in to 24 × 29 × 23¼ in as water content rises from 5.5 to 6.75 gal and weight from 370 to 431 lb. A heat-loss calculation decides between them; installation belongs with a licensed contractor.

Utica Boilers

Utica SVB-5

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Utica SVB-5 is a size in the current SVB Series 4 cast-iron water line: 150 MBH fixed input, 127 MBH heating capacity, a 109 MBH net AHRI water rating and 84% AFUE, with induced-draft chimney (4") or sidewall (3") venting. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Utica Boilers

Utica SVB-6

CurrentCanadian status unknown
Input
Output (max)
AFUE
84 %

The Utica SVB-6 is a size in the current SVB Series 4 cast-iron water line: 187.5 MBH fixed input, 158 MBH heating capacity, a 135 MBH net AHRI water rating and 84% AFUE, with induced-draft chimney (4") or sidewall (4") venting. It is tagged 'Current' on Utica's Gas Boilers category page.

Natural gasPropaneHeating-only

Frequently asked questions

What does the SVB-6 add over the SVB-5?

187.5 MBH input against 150 MBH, 158 MBH heating capacity against 127 MBH, and a 135 MBH net AHRI water rating against 109 MBH, per the official SVB Series 4 sell sheet.

Can both vent through a sidewall?

Yes — the induced-draft fan allows chimney or sidewall exhaust: SVB-5 uses 4" chimney and 3" sidewall; SVB-6 uses 4" chimney and 4" sidewall.

Are both boilers condensing?

No — every SVB Series 4 is a non-condensing cast-iron boiler with an induced-draft fan and chimney or sidewall exhaust.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.