Verdict in brief

Both the Utica UBSSC-050 and the Utica UBSSC-299 belong to the Utica Boilers SSC (UBSSC-050 to UBSSC-299) line of condensing boilers. The Utica UBSSC-050 is rated 10–50 MBH input and 95% AFUE, and the Utica UBSSC-299 is rated 60–299 MBH input and 95% AFUE. Utica UBSSC-299 lists 249 MBH more input than Utica UBSSC-050 (299 MBH against 50 MBH). Both list the same published AFUE of 95%.

Side by side

Published manufacturer figures. Input and output are kept separate; blanks mean the manufacturer did not publish that value.

Comparison of Utica UBSSC-050 and Utica UBSSC-299
SpecificationUtica UBSSC-050Utica UBSSC-299
Input, minimum10 MBH60 MBH
Input, maximum50 MBH299 MBH
AFUE95 %95 %
Turndown5:15:1
VentingDirect vent, sealed combustion; PVC, CPVC and polypropyleneDirect vent, sealed combustion; PVC, CPVC and polypropylene
Maximum allowable working pressure150 psi150 psi
Heat exchangerHigh-grade 316L/444 stainless steel fin coil with flame sight glassHigh-grade 316L/444 stainless steel fin coil with flame sight glass
MountingWall mounted — bracket includedWall mounted — bracket included
Built-in featuresPrimary/secondary manifold piping and pump; probe-type LWCO with test featurePrimary/secondary manifold piping and pump; probe-type LWCO with test feature

What actually separates them

Published ratings: the Utica UBSSC-050 is rated 10–50 MBH input and 95% AFUE; the Utica UBSSC-299 is rated 60–299 MBH input and 95% AFUE. Utica UBSSC-299 lists 249 MBH more input than Utica UBSSC-050 (299 MBH against 50 MBH). Both list the same published AFUE of 95%.

Both records print the same AFUE (95%), turndown (5:1), venting (Direct vent, sealed combustion; PVC, CPVC and polypropylene) and maximum allowable working pressure (150 psi), per the cited sources.

Utica Boilers

Utica UBSSC-050

CurrentCanadian status unknown
Input
10–50 MBH
Output (max)
AFUE
95 %

The Utica UBSSC-050 is a size in the SSC wall-hung condensing boiler line: 95.0% AFUE, 5:1 turndown, the patented 316L/444 stainless steel fin-coil heat exchanger and a built-in primary/secondary manifold with pump, documented with current documents on the official page.

Natural gasPropaneHeating-only

Utica Boilers

Utica UBSSC-299

CurrentCanadian status unknown
Input
60–299 MBH
Output (max)
AFUE
95 %

The Utica UBSSC-299 is a size in the SSC wall-hung condensing boiler line: 95.0% AFUE, 5:1 turndown, the patented 316L/444 stainless steel fin-coil heat exchanger and a built-in primary/secondary manifold with pump, documented with current documents on the official page.

Natural gasPropaneHeating-only

Frequently asked questions

Which of the two has the higher maximum input?

The Utica UBSSC-299 lists 299 MBH, against 50 MBH on the Utica UBSSC-050, per the cited documentation.

Which model is more efficient?

Both list the same AFUE of 95%.

Not sure which one fits your home?

A consultation includes a heat-loss review so the size is right the first time.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate